260 m³/h Airflow
Delivers 260 m³/h (153 CFM) from a 119 x 119 x 38 mm frame for general enclosure cooling.
Available to order
Request a QuoteNeed multiple units or help confirming a model? Contact our team.
Available payment methods
Shop with complete confidence. Whatever the reason, enjoy hassle-free returns and exchanges within 30 days. We cover all shipping costs for both returns and exchanges—no extra shipping fees, no worries.
Technical specifications, features, applications and purchasing information.
| Brand | Ebmpapst |
| Model Number | 4114NHH |
| Product Category | Axial Fan |
| Fan Type | DC Axial Fan |
| Rated Voltage | 24 VDC |
| Voltage Range | 16 to 30 VDC |
| Power Rating | 12.4 W |
| Dimensions | 119 x 119 x 38 mm |
| Airflow | 260 m³/h (153 CFM) |
| Speed | 5000 RPM |
| Noise Level | 60 dBA |
| Bearing Type | Ball Bearing |
| Protection Rating | IP20 |
| Connection | 2 Lead Wires |
| Operating Temperature | -20 to +65 °C |
Delivers 260 m³/h (153 CFM) from a 119 x 119 x 38 mm frame for general enclosure cooling.
Power rating of 12.4 W supports energy-conscious continuous fan operation.
Rated speed of 5000 RPM balances airflow delivery with acoustic output of 60 dBA.
IP20 rating for clean-air industrial environments and standard enclosure protection.
Features a locked rotor sensor for fault detection in DC fan monitoring systems.
We support online purchase of the Ebmpapst 4114NHH Axial Fan. If you need to make bulk purchases and inquire about other products, please contact our team to inform us of your purchase requirements. We will provide you with information such as quantity quotations, delivery dates, and transportation methods.
What is the Ebmpapst 4114NHH? It is a 24 VDC axial fan with a 119 x 119 x 38 mm frame.
What is the airflow of the 4114NHH? The airflow is 260 m³/h (153 CFM) at 5000 RPM.
What is the power rating? The power rating is 12.4 W.
What is the noise level? The noise level is 60 dBA.
What is the IP rating? The protection rating is IP20.
Does it have locked rotor sensing? Yes, it features a locked rotor sensor.
What is the operating temperature range? The range is -20 to +65 °C.
Send us your part number and technical requirements.