Dual-Channel Relay Output
Two independent relay contact outputs provide switching for safety-related circuits, each rated for the stated contact loading.
Available to order
Request a QuoteBulk Orders, Part Number Assistance, or Alternative Payment Options? Contact Our Team!
Shop with confidence. If for any reason you are not satisfied, you can take advantage of our hassle-free return and exchange service within 30 days. The seller covers all shipping costs for returns or exchanges—there are no extra shipping fees for you to pay, ensuring a worry-free shopping experience.
Available payment methods
Ships from 4 U.S. Warehouses – Contact Us for Estimated Delivery Times.
Technical specifications, features, applications and purchasing information.
| Brand | Pepperl+Fuchs |
| Model Number | KFD2-SR2-EX2.W |
| Product Category | Safety Relay |
| Signal Type | Digital Input |
| Number of Channels | 2-channel |
| Input Type | Dry contact, NAMUR sensor |
| Output Type | Relay contact, 2 outputs |
| Relay Contact Loading | 250 V AC / 2 A / cos φ > 0.75; 126.5 V AC / 4 A / cos φ > 0.75; 40 V DC / 2 A resistive |
| Rated Voltage | 19 to 30 V DC |
| Rated Current | ≤ 50 mA |
| Power Dissipation | ≤ 1 W |
| Safety Integrity Level | SIL 2 (SC 3), IEC/EN 61508 |
| Galvanic Isolation | Reinforced insulation, 300 Veff rated |
| Ambient Temperature | -40 to 70 °C |
| Degree of Protection | IP20 |
Two independent relay contact outputs provide switching for safety-related circuits, each rated for the stated contact loading.
Accepts dry contacts or NAMUR sensors according to EN 60947-5-6 for compatibility with common safety field devices.
Rated SIL 2 with systematic capability SC 3 according to IEC/EN 61508, supporting safety function implementation.
Detects breakage (≤ 0.1 mA) and short-circuit (> 6 mA) conditions on the input side for diagnostic coverage.
Operating mode is reversible, allowing adaptation to normally energized or normally de-energized safety logic.
Configuration is performed via DIP switches, with LED indication and front labeling space for commissioning.
We support online purchase of the Pepperl+Fuchs KFD2-SR2-EX2.W Safety Relay. If you need to make bulk purchases and inquire about other products, please contact our team to inform us of your purchase requirements. We will provide you with information such as quantity quotations, delivery dates, and transportation methods.
What is the Pepperl+Fuchs KFD2-SR2-EX2.W? It is a 2-channel switch amplifier and safety relay with relay contact outputs, designed for safety-related digital input signals from dry contacts or NAMUR sensors.
How many channels and outputs does the KFD2-SR2-EX2.W have? It has two input channels and two relay contact outputs.
What input types are accepted? The module accepts dry contacts and NAMUR sensors according to EN 60947-5-6.
What is the relay contact rating? Contacts are rated at 250 V AC / 2 A / cos φ > 0.75, 126.5 V AC / 4 A / cos φ > 0.75 and 40 V DC / 2 A resistive load.
What supply voltage does the KFD2-SR2-EX2.W require? It operates from 19 to 30 V DC via Power Rail or terminals 14+, 15-.
What is the SIL rating? The module is rated SIL 2 with systematic capability SC 3 according to IEC/EN 61508.
Does the KFD2-SR2-EX2.W provide line fault detection? Yes, it detects input breakage (≤ 0.1 mA) and short-circuit (> 6 mA).
What is the ambient temperature range? The operating ambient temperature range is -40 to 70 °C.
How is the module configured? Configuration is performed via DIP switches, with LED indicators for status.
Is the output mode reversible? Yes, the module supports reversible mode of operation for different safety logic arrangements.
What should be verified before ordering? Confirm the complete KFD2-SR2-EX2.W catalog number, input device type, required contact configuration, supply voltage and safety function requirements.