Shop with confidence. If for any reason you are not satisfied, you can take advantage of our hassle-free return and exchange service within 30 days. The seller covers all shipping costs for returns or exchanges—there are no extra shipping fees for you to pay, ensuring a worry-free shopping experience.
Available payment methods
Ships from 4 U.S. Warehouses – Contact Us for Estimated Delivery Times.
Technical specifications, features, applications and purchasing information.
| Brand | Pepperl+Fuchs |
| Model Number | UB1000-18GM75-U-V15 |
| Product Category | Ultrasonic Sensor |
| Product Family | UB1000-18GM75 Series |
| Sensing Range | 70 mm to 1000 mm |
| Adjustment Range | 90 mm to 1000 mm |
| Dead Band | 0 mm to 70 mm |
| Transducer Frequency | Approx. 255 kHz |
| Output Type | 1 analog output 0-10 V |
| Operating Voltage | 15 VDC to 30 VDC, ripple 10 %SS |
| No-Load Supply Current | ≤ 50 mA |
| Response Delay | Approx. 125 ms |
| Resolution | 0.35 mm |
| Repeat Accuracy | ± 0.1 % of full-scale value |
| Synchronization | 1 synchronous connection, bi-directional |
| Connection Type | Connector plug M12 x 1, 5-pin |
| Degree of Protection | IP67 |
| Housing Material | Brass, nickel-plated |
| Transducer Material | Epoxy resin/hollow glass sphere mixture; polyurethane foam |
| Ambient Temperature | -25 °C to 70 °C (-13 °F to 158 °F) |
| Storage Temperature | -40 °C to 85 °C (-40 °F to 185 °F) |
| Dimensions | Length 75 mm; Diameter 18 mm |
| Mass | 60 g |
Provides a 0-10 V voltage output proportional to the measured distance for direct interface with analog input modules and controllers.
The dead band is 0 mm to 70 mm, which the manufacturer identifies as a very small unusable area relative to the 1000 mm sensing range.
The sound lobe width is selectable, allowing adaptation to different target sizes and environmental conditions.
Evaluation limits A1 and A2 are adjustable via the program input, with factory settings of A1: 90 mm and A2: 1000 mm.
The 18 mm nickel-plated brass housing with IP67 protection supports installation in confined spaces exposed to dust and water spray.
Includes a bi-directional synchronization connection and a deactivation option for coordinated operation in multi-sensor systems.
We support online purchase of the Pepperl+Fuchs UB1000-18GM75-U-V15 Ultrasonic Sensor. If you need to make bulk purchases and inquire about other products, please contact our team to inform us of your purchase requirements. We will provide you with information such as quantity quotations, delivery dates, and transportation methods.
What is the sensing range of the UB1000-18GM75-U-V15? The sensing range is 70 mm to 1000 mm, with an adjustment range of 90 mm to 1000 mm.
What output type does this sensor provide? It provides one analog output of 0-10 V.
What is the resolution? The resolution is 0.35 mm.
What is the operating voltage? The operating voltage is 15 VDC to 30 VDC with a ripple of 10 %SS.
What is the dead band? The dead band is 0 mm to 70 mm.
What is the degree of protection? The degree of protection is IP67.
What is the housing material? The housing is nickel-plated brass.
What is the ambient temperature range? The ambient temperature range is -25 °C to 70 °C (-13 °F to 158 °F).
What connection type does it use? It uses an M12 x 1, 5-pin connector plug.
What is the transducer frequency? The transducer frequency is approximately 255 kHz.
Can the measuring window be adjusted? Yes. The evaluation limits A1 and A2 are adjustable via the program input, with default settings of 90 mm and 1000 mm.
What should be verified before ordering? Confirm the model number, sensing range and dead band, 0-10 V output compatibility, operating voltage, connector pinout, IP rating, ambient temperature limits, resolution requirement, and whether synchronization or deactivation will be used in the installation.