Skip to content
Honeywell

Honeywell R7861A1026 UV Flame Amplifier 120VAC 50/60Hz

PRODUCT PRICE USD
$333.75

Available to order

Stock: 400
Request a Quote

Bulk Orders, Part Number Assistance, or Alternative Payment Options? Contact Our Team!

Shop with confidence

30-Day Risk-Free Returns & Exchanges

Shop with confidence. If for any reason you are not satisfied, you can take advantage of our hassle-free return and exchange service within 30 days. The seller covers all shipping costs for returns or exchanges—there are no extra shipping fees for you to pay, ensuring a worry-free shopping experience.

View Our Return Policy

Payments

Available payment methods

  • PayPal
  • Bank transfer

💳 Need a Different Payment Method?Add your items to cart and contact our team before checkout. We'll help you explore available payment arrangements.

Service Guarantee

Shipping

Free standard shipping within the U.S

Shipping details

Estimated delivery

Ships from 4 U.S. Warehouses – Contact Us for Estimated Delivery Times.

Delivery details

Enjoy greater discounts on bulk orders

Please contact our team for bulk purchases

Contact our team
Honeywell R7861A1026 UV Flame Amplifier 120VAC 50/60Hz
PRODUCT DOCUMENTATION

Product Information

Technical specifications, features, applications and purchasing information.

Technical Specifications

Brand Honeywell
Model Number R7861A1026
Product Category UV Flame Amplifier
Product Series 7800 Series
Compatible Flame Sensor C7061 UV Flame Sensor
Compatible Control 7800 Series Primary Safety Control Relay Modules
Flame Signal Strength 0.0 to 5.0 VDC
Flame Failure Response Time 0.8 or 3.0 seconds
Self-Check Function Dynamic Self-Check
Mounting Style Plug-in, printed circuit board edge connector keyed
Operating Temperature Range -40°F to +140°F (-40°C to +60°C)
Supply Voltage (per title) 120VAC, 50/60Hz

Key Features

Dynamic Self-Check

The R7861A1026 incorporates a dynamic self-check function to support reliable flame supervision in compatible combustion safety systems.

UV Flame Signal Processing

Designed to interface with the C7061 ultraviolet flame sensor and provide a measurable flame signal output of 0.0 to 5.0 VDC.

Adjustable Response Time

Documented flame failure response times of 0.8 or 3.0 seconds are available depending on the application configuration.

Plug-In Installation

Connects directly to compatible 7800 Series relay modules through a keyed printed circuit board edge connector for proper orientation.

Flame Signal Test Jacks

Integrated test jacks allow measurement of the amplifier flame signal voltage during setup and troubleshooting.

Color-Coded Identification

Color-coded labels identify the flame detection type for quick visual verification in the control panel.

Applications

  • Industrial gas burner flame monitoring
  • Oil-fired burner safety systems
  • Coal-fired combustion equipment supervision
  • 7800 Series relay module flame safeguard circuits
  • UV flame detector integration with C7061 sensors
  • Commercial and industrial combustion control panels
  • Burner management systems requiring dynamic self-check
  • Flame signal verification and troubleshooting

Purchase Information

We support online purchase of the Honeywell R7861A1026 UV Flame Amplifier. If you need to make bulk purchases and inquire about other products, please contact our team to inform us of your purchase requirements. We will provide you with information such as quantity quotations, delivery dates, and transportation methods.

Frequently Asked Questions

What is the Honeywell R7861A1026? It is a plug-in UV flame signal amplifier designed for use with Honeywell 7800 Series primary safety control relay modules.

Which flame sensor is compatible? Honeywell documentation identifies the C7061 ultraviolet flame sensor as the compatible sensor for this amplifier.

What is the flame signal strength range? The documented flame signal strength range is 0.0 to 5.0 VDC.

Does it have a dynamic self-check feature? Yes, the R7861A1026 incorporates dynamic self-check functionality.

What are the available flame failure response times? Documented response times are 0.8 seconds or 3.0 seconds, depending on configuration.

How does the amplifier connect to the control system? It plugs into 7800 Series relay modules through a keyed printed circuit board edge connector.

What is the operating temperature range? The documented operating temperature range is -40°F to +140°F (-40°C to +60°C).

What is the supply voltage? The product title specifies 120VAC, 50/60Hz operation.

Can the flame signal be measured during service? Yes, the amplifier includes flame signal test jacks for measuring amplifier flame signal voltage.

What should be checked before ordering? Verify the complete R7861A1026 catalog number, compatibility with the existing 7800 Series relay module, sensor type, supply voltage, and flame failure response time requirements.

?
Need help confirming a model?

Send us your part number and technical requirements.

Contact Our Team