{"product_id":"bussmann-baf-2-fuse","title":"Bussmann BAF-2 2A 250Vac ACTING Fuse Industrial Supplier","description":"\u003ch2 style=\"text-align: center;\"\u003eEaton Bussmann BAF-2 2A 250V Fast-Acting Supplemental Fuse\u003c\/h2\u003e\n\u003cp\u003eBuy Eaton Bussmann BAF-2 fuse online.The Eaton Bussmann BAF-2 is a 2 amp, 250Vac fast-acting supplemental midget fuse designed for general-purpose circuits, lighting circuit protection, meter circuits and other compatible electrical equipment applications.\u003c\/p\u003e\n\u003cp\u003eFeaturing a compact 13\/32 inch × 1-1\/2 inch cylindrical format, the BAF-2 uses ferrule connections at both ends for installation in compatible midget fuse blocks, holders and fuse clips. Its fast-acting response is intended for applications that require prompt interruption of overcurrent without an intentional time delay.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCatalog Number:\u003c\/strong\u003e BAF-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Current:\u003c\/strong\u003e 2 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage Rating:\u003c\/strong\u003e 250 Vac\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Characteristic:\u003c\/strong\u003e Fast-acting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Category:\u003c\/strong\u003e Supplemental fuse\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Rating at 250 Vac:\u003c\/strong\u003e 100 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupting Rating at 125 Vac:\u003c\/strong\u003e 10 kA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Indicator:\u003c\/strong\u003e Non-indicating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Ferrule end to ferrule end\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Size:\u003c\/strong\u003e 13\/32 × 1-1\/2 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetric Size:\u003c\/strong\u003e 10.3 × 38.1 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTube Construction:\u003c\/strong\u003e Fiber tube\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEndcap Material:\u003c\/strong\u003e Nickel-plated brass\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Color Code:\u003c\/strong\u003e Green for 250Vac maximum voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 40%; text-align: left; border: 1px solid #dddddd; padding: 9px;\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 9px;\"\u003eEaton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border: 1px solid #dddddd; padding: 9px;\"\u003eBrand\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 9px;\"\u003eBussmann Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border: 1px solid #dddddd; padding: 9px;\"\u003eCatalog Number\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 9px;\"\u003eBAF-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border: 1px solid #dddddd; padding: 9px;\"\u003eSeries\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 9px;\"\u003eBAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border: 1px solid #dddddd; padding: 9px;\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 9px;\"\u003eFast-Acting Supplemental Midget Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border: 1px solid #dddddd; padding: 9px;\"\u003eAmperage Rating\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 9px;\"\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border: 1px solid #dddddd; padding: 9px;\"\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 9px;\"\u003e250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border: 1px solid #dddddd; padding: 9px;\"\u003eInterrupting Rating at 250 Vac\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 9px;\"\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border: 1px solid #dddddd; padding: 9px;\"\u003eInterrupting Rating at 125 Vac\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 9px;\"\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border: 1px solid #dddddd; padding: 9px;\"\u003eOperating Characteristic\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 9px;\"\u003eFast-acting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border: 1px solid #dddddd; padding: 9px;\"\u003eProtection Classification\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 9px;\"\u003eSupplemental protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border: 1px solid #dddddd; padding: 9px;\"\u003eFuse Indicator\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 9px;\"\u003eNon-indicating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border: 1px solid #dddddd; padding: 9px;\"\u003eConnection\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 9px;\"\u003eFerrule end × ferrule end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border: 1px solid #dddddd; padding: 9px;\"\u003eTube Construction\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 9px;\"\u003eFiber tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border: 1px solid #dddddd; padding: 9px;\"\u003eEndcap Material\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 9px;\"\u003eNickel-plated brass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border: 1px solid #dddddd; padding: 9px;\"\u003eSeries Color Code\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 9px;\"\u003eGreen, 250Vac maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border: 1px solid #dddddd; padding: 9px;\"\u003eCertifications and Compliance\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 9px;\"\u003eCSA Certified; CE marked\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; border: 1px solid #dddddd; padding: 9px;\"\u003eMinimum purchase quantity\u003c\/th\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 9px;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGeneral-purpose electrical circuits\u003c\/li\u003e\n\u003cli\u003eLighting circuit protection\u003c\/li\u003e\n\u003cli\u003eMeter circuits\u003c\/li\u003e\n\u003cli\u003eInstrumentation circuits\u003c\/li\u003e\n\u003cli\u003eControl equipment requiring supplemental protection\u003c\/li\u003e\n\u003cli\u003eReplacement applications that specifically specify BAF-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFast-Acting Overcurrent Protection\u003c\/h3\u003e\n\u003cp\u003eThe Bussmann BAF-2 uses a fast-acting operating characteristic. Unlike a time-delay fuse, it does not intentionally tolerate extended startup or inrush currents before opening.\u003c\/p\u003e\n\u003cp\u003eThis operating response makes the BAF-2 suitable for compatible general-purpose, lighting and meter circuits where the equipment manufacturer specifies a fast-acting supplemental fuse.\u003c\/p\u003e\n\u003ch3\u003eSupplemental Fuse Classification\u003c\/h3\u003e\n\u003cp\u003eThe BAF-2 is a supplemental fuse intended for use inside equipment or in applications where supplemental overcurrent protection is permitted. It should not be treated as a Class CC or other branch-circuit fuse.\u003c\/p\u003e\n\u003cp\u003eA supplemental fuse must not be used as a substitute where the electrical system requires a branch-circuit-rated overcurrent protective device. Always verify the equipment documentation and applicable electrical requirements before installation.\u003c\/p\u003e\n\u003ch3\u003eImportant Interrupting-Rating Information\u003c\/h3\u003e\n\u003cp\u003eThe BAF-2 has a published interrupting rating of \u003cstrong\u003e100 A at 250 Vac\u003c\/strong\u003e and \u003cstrong\u003e10 kA at 125 Vac\u003c\/strong\u003e. The interrupting rating changes with the applied system voltage and should not be interpreted as 10 kA at 250 Vac.\u003c\/p\u003e\n\u003cp\u003eBefore ordering or installing this fuse, confirm that the system voltage and available fault current remain within the published ratings of both the fuse and the installed fuse holder.\u003c\/p\u003e\n\u003ch3\u003eCompact Midget Fuse Format\u003c\/h3\u003e\n\u003cp\u003eThe BAF-2 uses the common 13\/32 inch × 1-1\/2 inch midget fuse format. Its ferrule terminals allow installation in compatible modular fuse blocks, DIN-rail holders, panel-mount holders, in-line holders and approved fuse clips.\u003c\/p\u003e\n\u003cp\u003ePhysical fit alone does not confirm electrical compatibility. Current rating, voltage rating, operating characteristic, fuse classification and interrupting rating must all match the application.\u003c\/p\u003e\n\u003ch3\u003eCompatible Fuse Blocks and Holders\u003c\/h3\u003e\n\u003cp\u003eCompatible Bussmann holder families for BAF supplemental midget fuses include BMM modular fuse blocks, CHM DIN-rail holders, HPM and HPS panel-mount holders, HEB and HEX in-line holders, and compatible PCB fuse clips.\u003c\/p\u003e\n\u003cp\u003eThe exact holder catalog number depends on pole count, mounting method, terminal configuration and required electrical ratings. Confirm the complete holder specification before installation.\u003c\/p\u003e\n\u003ch3\u003eBAF-2 Is Not a Class CC Fuse\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eBAF-2\u003c\/strong\u003e is a 2A, 250Vac fast-acting supplemental midget fuse. It should not be described or marketed as a Class CC, rejection-style or current-limiting branch-circuit fuse.\u003c\/p\u003e\n\u003cp\u003eOther fuse families may have similar physical dimensions but different voltage, interrupting and application ratings. Always verify the complete catalog number printed on the original fuse or specified by the equipment manufacturer.\u003c\/p\u003e\n\u003ch3\u003eCertifications and Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCSA Certified at 250 Vac\u003c\/li\u003e\n\u003cli\u003eCE marked\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 2A BAF-2 rating is not included in the BAF series UL Listed range. Eaton lists UL certification for BAF ratings from 3A through 15A.\u003c\/p\u003e\n\u003ch3\u003eImportant Selection Information\u003c\/h3\u003e\n\u003cp\u003eBefore purchasing, confirm the complete manufacturer catalog number \u003cstrong\u003eBAF-2\u003c\/strong\u003e, the required \u003cstrong\u003e2 amp rating\u003c\/strong\u003e, the \u003cstrong\u003e250Vac maximum voltage rating\u003c\/strong\u003e, the applicable interrupting rating and compatibility with the installed fuse holder.\u003c\/p\u003e\n\u003cp\u003eDo not select a replacement fuse solely by amperage, appearance or physical dimensions. The operating speed, voltage rating, fuse classification, interrupting rating and certification requirements must also be verified.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eOrder using the complete manufacturer part number \u003cstrong\u003eEaton Bussmann BAF-2\u003c\/strong\u003e. Confirm the required quantity, product condition and all electrical specifications before purchase or installation.\u003c\/p\u003e","brand":"Eaton Bussmann","offers":[{"title":"Default Title","offer_id":45514288070735,"sku":"CL5-BXS-BAF-2","price":13.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/7569\/2623\/files\/10_c7e09dd8-698d-4b06-b06c-9313cc5ad2e4.png?v=1780733387","url":"https:\/\/yunshuotrade.com\/products\/bussmann-baf-2-fuse","provider":"yunshuotrade","version":"1.0","type":"link"}