{"product_id":"allen-bradley-2080-tc2-module","title":"Allen-Bradley 2080-TC2 Micro800 Thermocouple Input Module  Fast ship","description":"\u003cstyle\u003e.nxs-industrial-product-page{--industrial-navy:#082f49;--industrial-blue:#0b4f7c;--industrial-blue-2:#0f6ea8;--industrial-cyan:#38bdf8;--steel-line:#c9dce9;--surface:#fff;--surface-soft:#f7fbfe;--text-main:#173042;--shadow-soft:0 10px 30px rgba(8,47,73,.08);--radius-lg:14px;--radius-md:10px}.nxs-industrial-product-page,.nxs-industrial-product-page *{box-sizing:border-box;font-family:Arial,Helvetica,sans-serif}.nxs-industrial-product-page{background:#f3f8fb;color:var(--text-main);line-height:1.75;-webkit-font-smoothing:antialiased}.nxs-industrial-product-page .container{width:92%;max-width:1120px;margin:0 auto;padding:8px 0 34px}.nxs-industrial-product-page .section{position:relative;overflow:hidden;background:var(--surface);margin:22px auto;padding:34px 30px;border:1px solid var(--steel-line);border-radius:var(--radius-lg);box-shadow:var(--shadow-soft)}.nxs-industrial-product-page .section:before{content:'';position:absolute;left:0;top:0;bottom:0;width:5px;background:linear-gradient(180deg,var(--industrial-cyan),var(--industrial-blue))}.nxs-industrial-product-page .section h2{font-size:25px;line-height:1.3;color:var(--industrial-navy);margin:0 0 22px;padding-bottom:12px;border-bottom:2px solid #e5f0f6}.nxs-industrial-product-page .spec-table{width:100%;border-collapse:collapse;background:#fff}.nxs-industrial-product-page .spec-table td{padding:12px 15px;border:1px solid #dbe7ef;vertical-align:top;color:#294658;overflow-wrap:anywhere}.nxs-industrial-product-page .spec-table tr:nth-child(even){background:#f7fbfe}.nxs-industrial-product-page .spec-table td:first-child{width:39%;font-weight:700;color:var(--industrial-blue);background:#edf5fa}.nxs-industrial-product-page .features{display:grid;grid-template-columns:repeat(auto-fit,minmax(235px,1fr));gap:18px}.nxs-industrial-product-page .card{background:linear-gradient(180deg,#fff,#f4f9fc);padding:21px 20px;border:1px solid #d5e4ee;border-top:4px solid var(--industrial-blue);border-radius:10px;box-shadow:0 6px 18px rgba(8,47,73,.05);transition:transform .2s,box-shadow .2s}.nxs-industrial-product-page .card:hover{transform:translateY(-3px);box-shadow:0 14px 30px rgba(8,79,124,.12)}.nxs-industrial-product-page .card h3{color:var(--industrial-blue);font-size:18px;line-height:1.4;margin:0 0 10px}.nxs-industrial-product-page .card p{color:#526a79;font-size:15px;margin:0}.nxs-industrial-product-page ul{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:11px 18px;padding:0;list-style:none}.nxs-industrial-product-page li{padding:12px 15px;background:var(--surface-soft);border:1px solid #dbe8f0;border-radius:8px;color:#365264}.nxs-industrial-product-page li:before{content:'◆';font-size:10px;color:var(--industrial-blue-2);margin-right:10px}.nxs-industrial-product-page .section:nth-of-type(4)\u003ep{padding:18px 20px;background:linear-gradient(135deg,#edf7fc,#f9fcfe);border:1px solid #cfe4f1;border-left:4px solid var(--industrial-blue-2);border-radius:9px;color:#355267}.nxs-industrial-product-page .section:last-of-type{counter-reset:faq}.nxs-industrial-product-page .section:last-of-type\u003ep{position:relative;padding:17px 18px 17px 54px;background:#f8fbfd;border:1px solid #d8e6ef;border-radius:9px;margin:0;counter-increment:faq}.nxs-industrial-product-page .section:last-of-type\u003ep:before{content:counter(faq,decimal-leading-zero);position:absolute;left:15px;top:17px;min-width:28px;height:28px;display:inline-flex;align-items:center;justify-content:center;border-radius:6px;background:var(--industrial-blue);color:#fff;font-size:11px;font-weight:700}.nxs-industrial-product-page .section:last-of-type strong{color:#0b456d}.nxs-industrial-product-page .section:last-of-type\u003ebr{display:block;content:'';margin:10px 0}@media(max-width:760px){.nxs-industrial-product-page .container{width:100%;padding:0 12px 24px}.nxs-industrial-product-page .section{padding:24px 15px;margin:14px auto}.nxs-industrial-product-page .section h2{font-size:21px}.nxs-industrial-product-page .spec-table{table-layout:fixed}.nxs-industrial-product-page .spec-table td{padding:10px 8px;font-size:13px}.nxs-industrial-product-page .spec-table td:first-child{width:43%}.nxs-industrial-product-page .features,.nxs-industrial-product-page ul{grid-template-columns:1fr}.nxs-industrial-product-page .card:hover{transform:none}.nxs-industrial-product-page .section:last-of-type\u003ep{padding:15px 13px 15px 48px;font-size:14px}.nxs-industrial-product-page .section:last-of-type\u003ep:before{left:11px;top:15px}}@media(prefers-reduced-motion:reduce){.nxs-industrial-product-page *{transition:none!important}}\u003c\/style\u003e\n\u003cdiv class=\"nxs-industrial-product-page\"\u003e\n\u003cdiv class=\"container\"\u003e\u003cmain\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2080-TC2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eThermocouple Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eMicro800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Series\u003c\/td\u003e\n\u003ctd\u003eBulletin 2080 Plug-In Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Product Description\u003c\/td\u003e\n\u003ctd\u003eMicro800 2-Channel Non-Isolated Thermocouple Input Plug-In\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Function\u003c\/td\u003e\n\u003ctd\u003eThermocouple Temperature Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channel Identification\u003c\/td\u003e\n\u003ctd\u003eChannel 0 and Channel 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eThermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Isolation\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Thermocouple Types\u003c\/td\u003e\n\u003ctd\u003eJ, K, N, T, E, R, S and B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Supported Thermocouple Types\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Thermocouple Type\u003c\/td\u003e\n\u003ctd\u003eType K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003eIndividually Configurable Thermocouple Type and Filter Frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog-to-Digital Resolution\u003c\/td\u003e\n\u003ctd\u003e14-Bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eGreater Than 300 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy at 25°C\u003c\/td\u003e\n\u003ctd\u003e±1.0°C Under Specified Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold Junction Compensation Error at 25°C\u003c\/td\u003e\n\u003ctd\u003e±1.2°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold Junction Compensation\u003c\/td\u003e\n\u003ctd\u003eExternal NTC Thermistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJC Sensor Connection\u003c\/td\u003e\n\u003ctd\u003eTerminals A3 and B3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCJC Arrangement\u003c\/td\u003e\n\u003ctd\u003eCommon Cold Junction Compensation for Both Thermocouple Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType K Temperature Measurement Range\u003c\/td\u003e\n\u003ctd\u003e-270 to +1370°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType K Range for ±1.0°C Accuracy\u003c\/td\u003e\n\u003ctd\u003e-200 to +1300°C at Specified ADC Update Rates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType J Temperature Measurement Range\u003c\/td\u003e\n\u003ctd\u003e-210 to +1200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType T Temperature Measurement Range\u003c\/td\u003e\n\u003ctd\u003e-270 to +400°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType E Temperature Measurement Range\u003c\/td\u003e\n\u003ctd\u003e-270 to +1000°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType N Temperature Measurement Range\u003c\/td\u003e\n\u003ctd\u003e-270 to +1300°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType R Temperature Measurement Range\u003c\/td\u003e\n\u003ctd\u003e-50 to +1760°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType S Temperature Measurement Range\u003c\/td\u003e\n\u003ctd\u003e-50 to +1760°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType B Temperature Measurement Range\u003c\/td\u003e\n\u003ctd\u003e+40 to +1820°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy Dependence\u003c\/td\u003e\n\u003ctd\u003eVaries with Thermocouple Type, Temperature and Configured ADC Update Rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection Ratio\u003c\/td\u003e\n\u003ctd\u003e100 dB at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Rejection Ratio\u003c\/td\u003e\n\u003ctd\u003e70 dB at 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-Circuit Detection\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-Circuit Detection Time\u003c\/td\u003e\n\u003ctd\u003e8 to 1515 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverrange Detection\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnderrange Detection\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Connection\u003c\/td\u003e\n\u003ctd\u003eMicro800 Controller Plug-In Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Current Consumption\u003c\/td\u003e\n\u003ctd\u003e40 mA at 3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolid Copper Wire Size\u003c\/td\u003e\n\u003ctd\u003e0.14 to 1.5 mm², 26 to 16 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStranded Copper Wire Size\u003c\/td\u003e\n\u003ctd\u003e0.14 to 1.0 mm², 26 to 17 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Wire Insulation Rating\u003c\/td\u003e\n\u003ctd\u003e90°C or Greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Wire Insulation Diameter\u003c\/td\u003e\n\u003ctd\u003e1.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Screw Torque\u003c\/td\u003e\n\u003ctd\u003e0.22 to 0.25 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Mounting Torque\u003c\/td\u003e\n\u003ctd\u003e0.2 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Sensor Wiring\u003c\/td\u003e\n\u003ctd\u003eShielded Thermocouple Wiring with Appropriate Grounding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Sensor Cable Length\u003c\/td\u003e\n\u003ctd\u003ePreferably Less Than 3 m for Improved Noise Immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemoval and Insertion Under Power\u003c\/td\u003e\n\u003ctd\u003eNot Supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Classification\u003c\/td\u003e\n\u003ctd\u003eOpen-Type Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Vibration\u003c\/td\u003e\n\u003ctd\u003e2 g at 10 to 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Operating Shock\u003c\/td\u003e\n\u003ctd\u003e25 g DIN Rail Mounted; 35 g Panel Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNorth American Temperature Code\u003c\/td\u003e\n\u003ctd\u003eT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrostatic Discharge Immunity\u003c\/td\u003e\n\u003ctd\u003e6 kV Contact and 8 kV Air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Emissions Classification\u003c\/td\u003e\n\u003ctd\u003eCISPR 11 Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e885630058467\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelated RTD Input Module\u003c\/td\u003e\n\u003ctd\u003e2080-RTD2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/section\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"features\"\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003eTwo Independent Thermocouple Input Channels\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 2080-TC2 provides two thermocouple measurement channels for compatible Micro800 programmable controllers. Each channel can be configured for its own supported sensor type and filter settings, allowing two separate process temperatures to be monitored.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003eEight Supported Thermocouple Types\u003c\/h3\u003e\n\u003cp\u003eThe module supports J, K, N, T, E, R, S and B thermocouples. This selection accommodates a variety of industrial temperature measurement applications, with each sensor type having its own specified temperature and accuracy ranges.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003e14-Bit Temperature Measurement Resolution\u003c\/h3\u003e\n\u003cp\u003eWith 14-bit analog-to-digital resolution, the module converts thermocouple signals into digital temperature data for the connected controller. Rockwell Automation specifies ±1.0°C measurement accuracy at 25°C under applicable conditions, with accuracy also dependent on sensor type and update rate.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003eExternal Cold Junction Compensation\u003c\/h3\u003e\n\u003cp\u003eThe 2080-TC2 uses an external NTC thermistor for cold junction compensation across both input channels. The thermistor connects to terminals A3 and B3 and must be installed correctly to obtain valid compensated thermocouple measurements.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003eTemperature Diagnostic Functions\u003c\/h3\u003e\n\u003cp\u003eOpen-circuit, overrange and underrange detection help identify disconnected sensors and readings outside the configured thermocouple measurement range. Corresponding diagnostic information can be accessed through compatible controller variables.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003eCompact Micro800 Plug-In Integration\u003c\/h3\u003e\n\u003cp\u003eThe plug-in design installs directly into a supported Micro800 controller slot without requiring a separate Bulletin 2085 expansion I\/O assembly. Configuration through Connected Components Workbench or supported FactoryTalk Design Workbench software helps integrate temperature feedback into PLC applications.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial oven and furnace temperature monitoring\u003c\/li\u003e\n\u003cli\u003ePackaging machinery heating-zone measurement\u003c\/li\u003e\n\u003cli\u003eIndustrial heating equipment temperature feedback\u003c\/li\u003e\n\u003cli\u003eManufacturing process temperature monitoring\u003c\/li\u003e\n\u003cli\u003eThermocouple-based PID temperature control\u003c\/li\u003e\n\u003cli\u003eEquipment thermal condition monitoring\u003c\/li\u003e\n\u003cli\u003eMicro800 PLC temperature input expansion\u003c\/li\u003e\n\u003cli\u003eMaintenance of thermocouple measurement systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003ePurchase Information\u003c\/h2\u003e\n\u003cp\u003eWe support online purchase of the Allen-Bradley 2080-TC2 Thermocouple Input Module. If you need to make bulk purchases and inquire about other products, please contact our team to inform us of your purchase requirements. We will provide you with information such as quantity quotations, delivery dates, and transportation methods.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the Allen-Bradley 2080-TC2?\u003c\/strong\u003e\u003cbr\u003eIt is a Rockwell Automation Micro800 plug-in temperature measurement module providing two non-isolated thermocouple input channels for compatible PLC controllers.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eHow many thermocouple inputs does the module have?\u003c\/strong\u003e\u003cbr\u003eThe module provides two input channels, Channel 0 and Channel 1. Each channel can be configured for a supported thermocouple type and measurement update setting.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhich thermocouple types are supported?\u003c\/strong\u003e\u003cbr\u003eThe 2080-TC2 supports Type J, K, N, T, E, R, S and B thermocouples. The default configuration is Type K.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the measurement resolution?\u003c\/strong\u003e\u003cbr\u003eThe module provides 14-bit analog-to-digital resolution. The accuracy and usable temperature range depend on the thermocouple type, temperature and configured conversion rate.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the specified measurement accuracy?\u003c\/strong\u003e\u003cbr\u003eRockwell Automation specifies ±1.0°C at 25°C under applicable conditions. The separate cold junction compensation error is ±1.2°C at 25°C, and sensor tolerance and installation conditions can contribute additional measurement error.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the measurement range for a Type K thermocouple?\u003c\/strong\u003e\u003cbr\u003eThe published Type K measurement range is -270 to +1370°C. The manufacturer identifies a narrower -200 to +1300°C range for the specified ±1.0°C accuracy conditions and applicable conversion rates.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 2080-TC2 require a cold junction compensation sensor?\u003c\/strong\u003e\u003cbr\u003eYes. An external NTC thermistor is used for cold junction compensation. The manufacturer describes this component as supplied with the module and specifies its installation between terminals A3 and B3.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eCan two different thermocouple types be connected simultaneously?\u003c\/strong\u003e\u003cbr\u003eYes. Each input channel is individually configurable, so the two channels can use different supported thermocouple types within the manufacturer's wiring and operating requirements.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhich Micro800 controllers are compatible?\u003c\/strong\u003e\u003cbr\u003eThe module is intended for supported Micro820, Micro830, Micro850 and Micro870 controller configurations with compatible plug-in slots. Confirm the exact controller catalog number and software compatibility before installation.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module be used for PID temperature control?\u003c\/strong\u003e\u003cbr\u003eYes. The module supplies thermocouple measurement data that a compatible Micro800 controller can use in a configured PID temperature control application. It is a measurement module, not a standalone temperature controller.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 2080-TC2 support RTD sensors such as Pt100?\u003c\/strong\u003e\u003cbr\u003eNo. The 2080-TC2 is intended for thermocouple sensors. Rockwell Automation provides the separate 2080-RTD2 module for supported resistance temperature detector inputs.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eAre the two thermocouple channels electrically isolated?\u003c\/strong\u003e\u003cbr\u003eNo. Rockwell Automation identifies the 2080-TC2 as a non-isolated thermocouple input module. Sensor grounding, shielding and installation methods must account for the shared electrical characteristics.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module support open-circuit detection?\u003c\/strong\u003e\u003cbr\u003eYes. The module reports open-circuit, overrange and underrange conditions through corresponding diagnostic information. Rockwell Automation specifies an open-circuit detection time ranging from 8 to 1515 ms.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require an external 24 VDC power supply?\u003c\/strong\u003e\u003cbr\u003eThe plug-in receives its operating power from the compatible controller interface. Rockwell Automation specifies a current consumption of 40 mA at 3.3 VDC.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 2080-TC2 be replaced while the controller is powered?\u003c\/strong\u003e\u003cbr\u003eNo. Removal and insertion under power are not supported. Disconnect the appropriate power sources and follow the manufacturer's installation procedures before replacing the module.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software is used to configure the module?\u003c\/strong\u003e\u003cbr\u003eThe module can be configured through compatible Connected Components Workbench or FactoryTalk Design Workbench software. Supported settings include thermocouple type and ADC update or filter frequency for each channel.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should be checked before ordering?\u003c\/strong\u003e\u003cbr\u003eConfirm catalog number 2080-TC2, two non-isolated thermocouple channels, required J\/K\/N\/T\/E\/R\/S\/B sensor compatibility, 14-bit resolution, compatible Micro800 controller and plug-in slot, CJC thermistor availability, temperature measurement range, software configuration requirements and correct field wiring. Verify the manufacturer's current installation documentation before commissioning.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/main\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67715652943951,"sku":"LL1-AB-2080TC2","price":98.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/7569\/2623\/files\/2080-TC2-01.jpg?v=1792045622","url":"https:\/\/yunshuotrade.com\/products\/allen-bradley-2080-tc2-module","provider":"yunshuotrade","version":"1.0","type":"link"}