{"product_id":"allen-bradley-2080-ps120-240vac-power-supply","title":"Allen-Bradley 2080-PS120-240VAC Micro800 Power Supply Fast Delivery","description":"\u003cstyle\u003e.nxs-industrial-product-page{--industrial-navy:#082f49;--industrial-blue:#0b4f7c;--industrial-blue-2:#0f6ea8;--industrial-cyan:#38bdf8;--steel-line:#c9dce9;--surface:#fff;--surface-soft:#f7fbfe;--text-main:#173042;--shadow-soft:0 10px 30px rgba(8,47,73,.08);--radius-lg:14px;--radius-md:10px}.nxs-industrial-product-page,.nxs-industrial-product-page *{box-sizing:border-box;font-family:Arial,Helvetica,sans-serif}.nxs-industrial-product-page{background:#f3f8fb;color:var(--text-main);line-height:1.75;-webkit-font-smoothing:antialiased}.nxs-industrial-product-page .container{width:92%;max-width:1120px;margin:0 auto;padding:8px 0 34px}.nxs-industrial-product-page .section{position:relative;overflow:hidden;background:var(--surface);margin:22px auto;padding:34px 30px;border:1px solid var(--steel-line);border-radius:var(--radius-lg);box-shadow:var(--shadow-soft)}.nxs-industrial-product-page .section:before{content:'';position:absolute;left:0;top:0;bottom:0;width:5px;background:linear-gradient(180deg,var(--industrial-cyan),var(--industrial-blue))}.nxs-industrial-product-page .section h2{font-size:25px;line-height:1.3;color:var(--industrial-navy);margin:0 0 22px;padding-bottom:12px;border-bottom:2px solid #e5f0f6}.nxs-industrial-product-page .spec-table{width:100%;border-collapse:collapse;background:#fff}.nxs-industrial-product-page .spec-table td{padding:12px 15px;border:1px solid #dbe7ef;vertical-align:top;color:#294658;overflow-wrap:anywhere}.nxs-industrial-product-page .spec-table tr:nth-child(even){background:#f7fbfe}.nxs-industrial-product-page .spec-table td:first-child{width:39%;font-weight:700;color:var(--industrial-blue);background:#edf5fa}.nxs-industrial-product-page .features{display:grid;grid-template-columns:repeat(auto-fit,minmax(235px,1fr));gap:18px}.nxs-industrial-product-page .card{background:linear-gradient(180deg,#fff,#f4f9fc);padding:21px 20px;border:1px solid #d5e4ee;border-top:4px solid var(--industrial-blue);border-radius:10px;box-shadow:0 6px 18px rgba(8,47,73,.05);transition:transform .2s,box-shadow .2s}.nxs-industrial-product-page .card:hover{transform:translateY(-3px);box-shadow:0 14px 30px rgba(8,79,124,.12)}.nxs-industrial-product-page .card h3{color:var(--industrial-blue);font-size:18px;line-height:1.4;margin:0 0 10px}.nxs-industrial-product-page .card p{color:#526a79;font-size:15px;margin:0}.nxs-industrial-product-page ul{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:11px 18px;padding:0;list-style:none}.nxs-industrial-product-page li{padding:12px 15px;background:var(--surface-soft);border:1px solid #dbe8f0;border-radius:8px;color:#365264}.nxs-industrial-product-page li:before{content:'◆';font-size:10px;color:var(--industrial-blue-2);margin-right:10px}.nxs-industrial-product-page .section:nth-of-type(4)\u003ep{padding:18px 20px;background:linear-gradient(135deg,#edf7fc,#f9fcfe);border:1px solid #cfe4f1;border-left:4px solid var(--industrial-blue-2);border-radius:9px;color:#355267}.nxs-industrial-product-page .section:last-of-type{counter-reset:faq}.nxs-industrial-product-page .section:last-of-type\u003ep{position:relative;padding:17px 18px 17px 54px;background:#f8fbfd;border:1px solid #d8e6ef;border-radius:9px;margin:0;counter-increment:faq}.nxs-industrial-product-page .section:last-of-type\u003ep:before{content:counter(faq,decimal-leading-zero);position:absolute;left:15px;top:17px;min-width:28px;height:28px;display:inline-flex;align-items:center;justify-content:center;border-radius:6px;background:var(--industrial-blue);color:#fff;font-size:11px;font-weight:700}.nxs-industrial-product-page .section:last-of-type strong{color:#0b456d}.nxs-industrial-product-page .section:last-of-type\u003ebr{display:block;content:'';margin:10px 0}@media(max-width:760px){.nxs-industrial-product-page .container{width:100%;padding:0 12px 24px}.nxs-industrial-product-page .section{padding:24px 15px;margin:14px auto}.nxs-industrial-product-page .section h2{font-size:21px}.nxs-industrial-product-page .spec-table{table-layout:fixed}.nxs-industrial-product-page .spec-table td{padding:10px 8px;font-size:13px}.nxs-industrial-product-page .spec-table td:first-child{width:43%}.nxs-industrial-product-page .features,.nxs-industrial-product-page ul{grid-template-columns:1fr}.nxs-industrial-product-page .card:hover{transform:none}.nxs-industrial-product-page .section:last-of-type\u003ep{padding:15px 13px 15px 48px;font-size:14px}.nxs-industrial-product-page .section:last-of-type\u003ep:before{left:11px;top:15px}}@media(prefers-reduced-motion:reduce){.nxs-industrial-product-page *{transition:none!important}}\u003c\/style\u003e\n\u003cdiv class=\"nxs-industrial-product-page\"\u003e\n\u003cdiv class=\"container\"\u003e\u003cmain\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2080-PS120-240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eIndustrial Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eMicro800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eBulletin 2080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Description\u003c\/td\u003e\n\u003ctd\u003eMicro800 120\/240 VAC to 24 VDC External Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage, Low Range\u003c\/td\u003e\n\u003ctd\u003e100–120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Current, Low Range\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage, High Range\u003c\/td\u003e\n\u003ctd\u003e200–240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Current, High Range\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermitted Supply Fluctuation Limits\u003c\/td\u003e\n\u003ctd\u003e85–264 VAC, According to Installation Instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Supply Frequency\u003c\/td\u003e\n\u003ctd\u003e47–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e1.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Power\u003c\/td\u003e\n\u003ctd\u003e38.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDC Power for Compatible Industrial Control Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Safety Classification\u003c\/td\u003e\n\u003ctd\u003eSELV, According to IEC 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current at 132 VAC\u003c\/td\u003e\n\u003ctd\u003e24 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current at 263 VAC\u003c\/td\u003e\n\u003ctd\u003e40 A for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Published Input Power at 100 VAC\u003c\/td\u003e\n\u003ctd\u003e45.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Published Input Power at 240 VAC\u003c\/td\u003e\n\u003ctd\u003e44.0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power at 100 VAC\u003c\/td\u003e\n\u003ctd\u003e38.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Power at 240 VAC\u003c\/td\u003e\n\u003ctd\u003e38.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary-to-Secondary Isolation\u003c\/td\u003e\n\u003ctd\u003eReinforced Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Isolation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Type Test\u003c\/td\u003e\n\u003ctd\u003eSee Applicable Manufacturer Document Revision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundant Power Supply Configuration\u003c\/td\u003e\n\u003ctd\u003eNot Supported as an Integrated Redundancy Feature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Function Power Supply\u003c\/td\u003e\n\u003ctd\u003eNot Rated for Safety Functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Terminal PAC-1\u003c\/td\u003e\n\u003ctd\u003eAC Line \/ Hot (L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Terminal PAC-2\u003c\/td\u003e\n\u003ctd\u003eAC Neutral (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Terminal PAC-3\u003c\/td\u003e\n\u003ctd\u003eProtective Earth (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Output Terminal DC-1\u003c\/td\u003e\n\u003ctd\u003e+24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Output Terminal DC-2\u003c\/td\u003e\n\u003ctd\u003e+24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Output Terminal DC-3\u003c\/td\u003e\n\u003ctd\u003e0 VDC \/ Negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Output Terminal DC-4\u003c\/td\u003e\n\u003ctd\u003e0 VDC \/ Negative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connector Arrangement\u003c\/td\u003e\n\u003ctd\u003eTwo Positive and Two Negative DC Output Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Category\u003c\/td\u003e\n\u003ctd\u003eCategory 2 on Power Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolid Copper Wire Size\u003c\/td\u003e\n\u003ctd\u003e0.32–2.1 mm², 22–14 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStranded Copper Wire Size\u003c\/td\u003e\n\u003ctd\u003e0.32–1.3 mm², 22–16 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Insulation Temperature Rating\u003c\/td\u003e\n\u003ctd\u003e90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Stripping Length\u003c\/td\u003e\n\u003ctd\u003e7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Screw Torque\u003c\/td\u003e\n\u003ctd\u003e0.5–0.6 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Conductors per Terminal\u003c\/td\u003e\n\u003ctd\u003e2, Subject to Manufacturer Wiring Requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Height\u003c\/td\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Width\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Depth\u003c\/td\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate Product Weight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg, Manufacturer Product Catalog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Classification\u003c\/td\u003e\n\u003ctd\u003eOpen-Type Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Methods\u003c\/td\u003e\n\u003ctd\u003eDIN Rail or Panel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible DIN Rail\u003c\/td\u003e\n\u003ctd\u003e35 × 7.5 mm, EN 50022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel Mounting Hardware\u003c\/td\u003e\n\u003ctd\u003eTwo M4 \/ #8 Screws, According to February 2024 Instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Ventilation Clearance\u003c\/td\u003e\n\u003ctd\u003eApproximately 50 mm, Except on Controller Connection Side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Ambient Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5–95%, Noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Vibration\u003c\/td\u003e\n\u003ctd\u003e2 g at 10–500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Installation Altitude Without Derating\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Environment\u003c\/td\u003e\n\u003ctd\u003ePollution Degree 2, Overvoltage Category II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESD Immunity\u003c\/td\u003e\n\u003ctd\u003e6 kV Contact; 8 kV Air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Immunity on Power Ports\u003c\/td\u003e\n\u003ctd\u003e±1 kV Line-to-Line; ±2 kV Line-to-Earth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Fast Transient Immunity\u003c\/td\u003e\n\u003ctd\u003e±2 kV at 5 kHz on Power Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Emissions\u003c\/td\u003e\n\u003ctd\u003eCISPR 11 Group 1, Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNorth American Temperature Code\u003c\/td\u003e\n\u003ctd\u003eT4A, According to Installation Instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e885630058382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/section\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"features\"\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003e24 VDC \/ 1.6 A Regulated Output\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 2080-PS120-240VAC converts an appropriate AC supply into 24 VDC output power for compatible Micro800 programmable controllers and associated control equipment. Its maximum output rating is 1.6 A or 38.4 W, making load-budget verification important during installation.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003e120\/240 VAC Input Flexibility\u003c\/h3\u003e\n\u003cp\u003eThe power supply supports nominal 100–120 VAC and 200–240 VAC input ranges at 47–63 Hz. This flexibility accommodates common industrial control-panel AC supply arrangements, provided that the electrical installation remains within the manufacturer's specified input limits.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003eReinforced Primary-to-Secondary Isolation\u003c\/h3\u003e\n\u003cp\u003eThe unit provides reinforced insulation between the AC input and DC output circuits. Rockwell Automation specifies a continuous isolation voltage of 250 V and identifies the DC output as meeting SELV requirements under the applicable standard.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003eConvenient DC Power Connections\u003c\/h3\u003e\n\u003cp\u003eThe output terminals provide two positive and two negative 24 VDC connection points, while the AC input provides line, neutral and protective earth connections. These connections support appropriately wired Micro800 controller power arrangements within the 1.6 A total output limit.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003eCompact DIN Rail and Panel Mounting\u003c\/h3\u003e\n\u003cp\u003eMeasuring 90 × 45 × 80 mm, the power supply supports vertical mounting on a standard 35 mm DIN rail or a suitable control panel. Rockwell Automation specifies installation clearances to provide adequate ventilation in industrial enclosures.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003eIndustrial Operating Environment\u003c\/h3\u003e\n\u003cp\u003eThe IP20 unit is specified for operation from -20 to +65°C with 5–95% noncondensing relative humidity. Its industrial EMC and environmental specifications support appropriate control-cabinet applications with correct grounding, wiring and protective enclosure design.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMicro800 PLC controller power supply systems\u003c\/li\u003e\n\u003cli\u003eMicro830 and Micro850 control panel power arrangements\u003c\/li\u003e\n\u003cli\u003eMicro870 PLC and compatible expansion I\/O installations\u003c\/li\u003e\n\u003cli\u003eIndustrial machine control cabinet DC power distribution\u003c\/li\u003e\n\u003cli\u003ePackaging machinery PLC power systems\u003c\/li\u003e\n\u003cli\u003eConveyor and material handling control panels\u003c\/li\u003e\n\u003cli\u003eManufacturing automation controller installations\u003c\/li\u003e\n\u003cli\u003eMaintenance and replacement of Micro800 power supplies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003ePurchase Information\u003c\/h2\u003e\n\u003cp\u003eWe support online purchase of the Allen-Bradley 2080-PS120-240VAC Industrial Power Supply. If you need to make bulk purchases and inquire about other products, please contact our team to inform us of your purchase requirements. We will provide you with information such as quantity quotations, delivery dates, and transportation methods.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the Allen-Bradley 2080-PS120-240VAC?\u003c\/strong\u003e\u003cbr\u003eIt is a Rockwell Automation Micro800 external AC-to-DC power supply designed to provide 24 VDC power for compatible programmable controllers and expansion I\/O systems.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated output voltage?\u003c\/strong\u003e\u003cbr\u003eThe rated output is 24 VDC. It is an AC-input, DC-output power supply and should not be confused with an AC-output power module.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum output current?\u003c\/strong\u003e\u003cbr\u003eThe manufacturer specifies 1.6 A maximum output current, corresponding to a maximum output power of 38.4 W at 24 VDC.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat input voltage does the power supply accept?\u003c\/strong\u003e\u003cbr\u003eRockwell Automation lists nominal input ranges of 100–120 VAC at 1 A and 200–240 VAC at 0.5 A. Its installation instructions also state that source-voltage fluctuations must remain within 85–264 VAC.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the supported AC input frequency?\u003c\/strong\u003e\u003cbr\u003eThe specified frequency range is 47–63 Hz, covering common nominal 50 Hz and 60 Hz industrial supplies.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eCan the power supply be used with Micro850 and Micro870 controllers?\u003c\/strong\u003e\u003cbr\u003eYes. It is intended for compatible Micro800 controller power arrangements. Controller selection, optional expansion I\/O and the combined power requirement must be checked against the 38.4 W output capacity.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eCan it power expansion I\/O modules?\u003c\/strong\u003e\u003cbr\u003eIt can supply compatible Micro800 controller and expansion-system power arrangements, but it does not replace the expansion backplane or any separately required expansion power supply. The complete electrical design must meet the applicable controller and I\/O power requirements.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the power supply provide two separate 24 VDC outputs?\u003c\/strong\u003e\u003cbr\u003eIt provides two positive and two negative DC output terminals. These should not be interpreted as two independently rated 1.6 A outputs; the total rated supply output is 24 VDC at 1.6 A.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eHow are the AC input terminals arranged?\u003c\/strong\u003e\u003cbr\u003ePAC-1 is the AC line or hot terminal, PAC-2 is the AC neutral terminal and PAC-3 is protective earth. Proper grounding is mandatory, and installation must follow the manufacturer wiring diagram and applicable electrical codes.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the DC output terminal assignments?\u003c\/strong\u003e\u003cbr\u003eDC-1 and DC-2 are positive 24 VDC terminals, while DC-3 and DC-4 are negative terminals. Verify terminal markings and polarity before energizing connected equipment.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 2080-PS120-240VAC provide electrical isolation?\u003c\/strong\u003e\u003cbr\u003eYes. Rockwell Automation specifies reinforced primary-to-secondary insulation, a 250 V continuous isolation rating and a SELV-classified DC output under the applicable product documentation.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eCan this power supply be used for safety-rated circuits?\u003c\/strong\u003e\u003cbr\u003eRockwell Automation identifies the product as not suitable for safety functions. Safety-related power requirements must be evaluated using components specifically approved for the intended safety architecture.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module be mounted on a DIN rail?\u003c\/strong\u003e\u003cbr\u003eYes. It supports a 35 × 7.5 mm DIN rail and panel mounting. The February 2024 installation instructions specify vertical installation and describe panel mounting with two M4 or #8 screws.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the dimensions and weight?\u003c\/strong\u003e\u003cbr\u003eThe power supply measures 90 mm high, 45 mm wide and 80 mm deep. Rockwell Automation's product catalog lists an approximate weight of 0.34 kg; consult the applicable document revision for shipping-weight information.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eThe specified operating temperature range is -20 to +65°C, with 5–95% noncondensing relative humidity. Suitable cabinet ventilation must be provided according to Rockwell Automation installation instructions.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between 2080-PS120-240VAC and 2080-PSAC-12W?\u003c\/strong\u003e\u003cbr\u003eThe 2080-PS120-240VAC provides a maximum of 24 VDC at 1.6 A or 38.4 W. The 2080-PSAC-12W is a different lower-power supply with temperature-dependent output ratings. They should not be substituted without checking the power budget and installation specifications.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 2080-PS120-240VAC discontinued?\u003c\/strong\u003e\u003cbr\u003eRockwell Automation currently lists the 2080-PS120-240VAC as an Active product in its catalog. Lifecycle status should be reconfirmed when planning future equipment maintenance.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should be checked before ordering?\u003c\/strong\u003e\u003cbr\u003eConfirm catalog number 2080-PS120-240VAC, 100–120 VAC or 200–240 VAC nominal input supply, 47–63 Hz frequency, 24 VDC output, 1.6 A maximum current, 38.4 W power rating, Micro800 controller compatibility, total connected load, terminal polarity, protective-earth wiring, IP20 enclosure, 90 × 45 × 80 mm dimensions and suitable mounting and ventilation arrangements.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/main\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67715757473871,"sku":"LL1-AB-2080PS120240VAC","price":51.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/7569\/2623\/files\/2080-PS120-240VAC-01.jpg?v=1792046796","url":"https:\/\/yunshuotrade.com\/products\/allen-bradley-2080-ps120-240vac-power-supply","provider":"yunshuotrade","version":"1.0","type":"link"}