{"product_id":"allen-bradley-150-c30nbr-controller","title":"Allen-Bradley Brand New 150-C30NBR  Smart Motor Controller","description":"\u003cstyle\u003e.nxs-industrial-product-page{--industrial-navy:#082f49;--industrial-blue:#0b4f7c;--industrial-blue-2:#0f6ea8;--industrial-blue-3:#1784c1;--industrial-cyan:#38bdf8;--steel-blue:#dcebf5;--steel-line:#c9dce9;--surface:#fff;--surface-soft:#f7fbfe;--text-main:#173042;--shadow-soft:0 10px 30px rgba(8,47,73,.08);--shadow-hover:0 16px 36px rgba(8,79,124,.15);--radius-lg:14px;--radius-md:10px}.nxs-industrial-product-page,.nxs-industrial-product-page *{margin:0;padding:0;box-sizing:border-box;font-family:Arial,Helvetica,sans-serif}.nxs-industrial-product-page{background:linear-gradient(180deg,#eef6fb 0,#f7fafc 320px,#eef3f7 100%);position:relative;overflow:hidden;color:var(--text-main);line-height:1.75;-webkit-font-smoothing:antialiased}.nxs-industrial-product-page .container{width:92%;max-width:1120px;margin:0 auto;padding-bottom:34px}.nxs-industrial-product-page main{padding-top:8px}.nxs-industrial-product-page .section{position:relative;overflow:hidden;background:var(--surface);margin:22px auto;padding:36px 30px;border:1px solid var(--steel-line);border-radius:var(--radius-lg);box-shadow:var(--shadow-soft)}.nxs-industrial-product-page .section::before{content:'';position:absolute;left:0;top:0;width:5px;height:100%;background:linear-gradient(180deg,var(--industrial-blue-3),var(--industrial-blue))}.nxs-industrial-product-page .section h2{display:inline-flex;align-items:center;gap:10px;font-size:25px;line-height:1.3;color:var(--industrial-navy);margin-bottom:24px}.nxs-industrial-product-page .section h2::before{content:'';width:28px;height:4px;flex:0 0 28px;border-radius:999px;background:linear-gradient(90deg,var(--industrial-blue-2),var(--industrial-cyan))}.nxs-industrial-product-page .spec-table{width:100%;border-collapse:separate;border-spacing:0;overflow:hidden;border:1px solid var(--steel-line);border-radius:var(--radius-md);background:#fff}.nxs-industrial-product-page .spec-table tr:nth-child(even){background:#f7fbfe}.nxs-industrial-product-page .spec-table tr:hover{background:#eaf5fb}.nxs-industrial-product-page .spec-table td{padding:13px 16px;border-bottom:1px solid #dbe7ef;vertical-align:top;color:#294658}.nxs-industrial-product-page .spec-table tr:last-child td{border-bottom:none}.nxs-industrial-product-page .spec-table td:first-child{width:38%;font-weight:700;color:#0b456d;background:rgba(220,235,245,.42)}.nxs-industrial-product-page .features{display:grid;grid-template-columns:repeat(auto-fit,minmax(235px,1fr));gap:18px}.nxs-industrial-product-page .card{position:relative;overflow:hidden;background:linear-gradient(180deg,#fff,#f4f9fc);padding:22px 20px;border:1px solid #d5e4ee;border-radius:var(--radius-md);box-shadow:0 6px 18px rgba(8,47,73,.055);transition:transform .22s,box-shadow .22s}.nxs-industrial-product-page .card::before{content:'';position:absolute;left:0;top:0;width:100%;height:4px;background:linear-gradient(90deg,var(--industrial-blue),var(--industrial-cyan))}.nxs-industrial-product-page .card:hover{transform:translateY(-4px);box-shadow:var(--shadow-hover)}.nxs-industrial-product-page .card h3{color:var(--industrial-blue);font-size:18px;line-height:1.35;margin-bottom:10px;border-left:4px solid var(--industrial-blue-3);padding-left:12px}.nxs-industrial-product-page .card p{color:#526a79;font-size:15px}.nxs-industrial-product-page .section ul{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:11px 18px;list-style:none}.nxs-industrial-product-page .section li{position:relative;padding:12px 14px 12px 38px;background:var(--surface-soft);border:1px solid #dbe8f0;border-radius:8px;color:#365264}.nxs-industrial-product-page .section li::before{content:'';position:absolute;left:15px;top:50%;width:9px;height:9px;transform:translateY(-50%) rotate(45deg);background:var(--industrial-blue-2)}.nxs-industrial-product-page .section:nth-of-type(4) p{padding:18px 20px;background:linear-gradient(135deg,#edf7fc,#f9fcfe);border:1px solid #cfe4f1;border-left:4px solid var(--industrial-blue-2);border-radius:9px;color:#355267}.nxs-industrial-product-page .section:last-of-type{counter-reset:faq}.nxs-industrial-product-page .section:last-of-type\u003ep{position:relative;padding:18px 18px 18px 54px;background:#f8fbfd;border:1px solid #d8e6ef;border-radius:9px;counter-increment:faq}.nxs-industrial-product-page .section:last-of-type\u003ep::before{content:counter(faq,decimal-leading-zero);position:absolute;left:15px;top:17px;min-width:28px;height:28px;display:inline-flex;align-items:center;justify-content:center;border-radius:6px;background:var(--industrial-blue);color:#fff;font-size:11px;font-weight:700}.nxs-industrial-product-page .section:last-of-type\u003ep strong{display:inline-block;color:#0b456d;margin-bottom:5px;line-height:1.4}.nxs-industrial-product-page .section:last-of-type\u003ebr{display:block;content:'';margin:10px 0}@media(max-width:760px){.nxs-industrial-product-page .container{width:100%;padding:0 12px 24px}.nxs-industrial-product-page .section{padding:26px 17px 24px;margin:14px auto;border-radius:11px}.nxs-industrial-product-page .section h2{font-size:21px;margin-bottom:18px}.nxs-industrial-product-page .section h2::before{width:20px;flex-basis:20px}.nxs-industrial-product-page .spec-table{table-layout:fixed}.nxs-industrial-product-page .spec-table td{padding:11px 9px;font-size:13px;overflow-wrap:anywhere}.nxs-industrial-product-page .spec-table td:first-child{width:42%}.nxs-industrial-product-page .features,.nxs-industrial-product-page .section ul{grid-template-columns:1fr;gap:12px}.nxs-industrial-product-page .card{padding:18px 17px}.nxs-industrial-product-page .card:hover{transform:none}.nxs-industrial-product-page .section li{font-size:14px}.nxs-industrial-product-page .section:last-of-type\u003ep{padding:16px 14px 16px 48px;font-size:14px}.nxs-industrial-product-page .section:last-of-type\u003ep::before{left:12px;top:15px;min-width:26px;height:26px;font-size:10px}}@media(prefers-reduced-motion:reduce){.nxs-industrial-product-page *{transition:none!important}}\u003c\/style\u003e\n\u003cdiv class=\"nxs-industrial-product-page\"\u003e\n\u003cdiv class=\"container\"\u003e\u003cmain\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e150-C30NBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eSmart Motor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eSMC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Bulletin\u003c\/td\u003e\n\u003ctd\u003eBulletin 150-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Type\u003c\/td\u003e\n\u003ctd\u003eSolid-State Smart Motor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Controller Current\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Main Power Voltage\u003c\/td\u003e\n\u003ctd\u003e480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Power Voltage Class\u003c\/td\u003e\n\u003ctd\u003e200-480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Circuit\u003c\/td\u003e\n\u003ctd\u003eThree-Phase, 3-Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Current During Starting with Fan\u003c\/td\u003e\n\u003ctd\u003e800 mA at 24 VDC; 660 mA at 24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Current During Starting without Fan\u003c\/td\u003e\n\u003ctd\u003e705 mA at 24 VDC; 580 mA at 24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Input ON-State Current\u003c\/td\u003e\n\u003ctd\u003e7.3 mA at 24 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Control Input ON-State Voltage\u003c\/td\u003e\n\u003ctd\u003e19.2 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine-Connected Motor Current Range\u003c\/td\u003e\n\u003ctd\u003e10-30 A at 380\/400\/415\/460 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInside-Delta Motor Current Range\u003c\/td\u003e\n\u003ctd\u003e17.3-52 A at 380\/400\/415\/460 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine-Connected Motor Power at 460VAC\u003c\/td\u003e\n\u003ctd\u003e7.5-20 HP at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInside-Delta Motor Power at 460VAC\u003c\/td\u003e\n\u003ctd\u003e7.5-30 HP at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting Duty\u003c\/td\u003e\n\u003ctd\u003e350% of Motor Full-Load Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelectable Current Limit\u003c\/td\u003e\n\u003ctd\u003e150%, 250%, 350% and 450% of Motor Full-Load Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelectable Start Times\u003c\/td\u003e\n\u003ctd\u003e2, 5, 10, 15, 20, 25 and 30 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelectable Initial Torque\u003c\/td\u003e\n\u003ctd\u003e15%, 25%, 35% and 65% of Locked-Rotor Torque\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelectable Kick Start Duration\u003c\/td\u003e\n\u003ctd\u003eOff, 0.5, 1.0 or 1.5 Seconds at 450% FLA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoft Stop Configuration\u003c\/td\u003e\n\u003ctd\u003eOff, 100%, 200% or 300% of Selected Start Time When Wired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Motor Overload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelectable Overload Trip Classes\u003c\/td\u003e\n\u003ctd\u003eClass 10, 15 and 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Bypass\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Rotation Control\u003c\/td\u003e\n\u003ctd\u003eSingle Direction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Overload\/Fault Contact\u003c\/td\u003e\n\u003ctd\u003e1 Normally Open Contact at Terminals 97-98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contact Conventional Thermal Current\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contact Operational Rating\u003c\/td\u003e\n\u003ctd\u003e0.6 A at 120 VAC; 0.3 A at 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contact Make Capacity\u003c\/td\u003e\n\u003ctd\u003e432 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contact Break Capacity\u003c\/td\u003e\n\u003ctd\u003e72 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Display\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Configuration\u003c\/td\u003e\n\u003ctd\u003eOpen Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e600 VAC per UL\/CSA\/NEMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Circuit Dielectric Withstand\u003c\/td\u003e\n\u003ctd\u003e2500 VAC per IEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Circuit dV\/dt Protection\u003c\/td\u003e\n\u003ctd\u003e1000 V\/µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Capacity Short-Circuit Rating\u003c\/td\u003e\n\u003ctd\u003eUp to 70 kA at 600 V with Applicable Maximum 60 A Time-Delay Class J or L Fuse for Line-Connected Motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Installation Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteady-State Heat Dissipation\u003c\/td\u003e\n\u003ctd\u003e19 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Terminal Conductor Size\u003c\/td\u003e\n\u003ctd\u003e2.5-25 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Terminal Tightening Torque\u003c\/td\u003e\n\u003ctd\u003e2.3-3.4 Nm; 4.0 Nm for 25 mm² Wire in Top Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hole Diameter\u003c\/td\u003e\n\u003ctd\u003e4.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e139.7 × 44.8 × 110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.86 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Documentation\u003c\/td\u003e\n\u003ctd\u003e150-IN030 Installation Instructions; 150-TD009 Technical Data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Product Reference\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.rockwellautomation.com\/en-us\/products\/details.150-C30NBR.html\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eRockwell Automation 150-C30NBR Product Specifications\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/section\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"features\"\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003e30A Three-Phase Motor Starting\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley SMC-3 150-C30NBR provides a 30 A controller rating for compatible three-phase induction motors, with a documented line-connected motor current range of 10-30 A at specified supply voltages.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003e24V AC\/DC Control Supply\u003c\/h3\u003e\n\u003cp\u003eThe controller operates with a 24 V AC\/DC control supply and supports a nominal 480 VAC three-phase main power circuit. This configuration is distinct from versions requiring 100-240 VAC control power.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003eIntegrated Motor Bypass\u003c\/h3\u003e\n\u003cp\u003eThe internal bypass reduces thyristor conduction losses once the motor reaches its normal running condition, helping limit operating heat generation and power dissipation.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003eAdjustable Starting and Soft Stopping\u003c\/h3\u003e\n\u003cp\u003eSelectable current limits of 150-450% of motor full-load current, starting times from 2 to 30 seconds, adjustable initial torque and configurable soft stopping support a variety of mechanical loads.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003eIntegrated Overload Protection\u003c\/h3\u003e\n\u003cp\u003eThe SMC-3 includes electronic motor overload protection with selectable Class 10, 15 and 20 trip characteristics. A normally open fault contact provides an interface for supported monitoring and control circuits.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003eCompact IP2X Construction\u003c\/h3\u003e\n\u003cp\u003eThe open-type controller measures 139.7 × 44.8 × 110 mm and weighs approximately 0.86 kg. It has an IP2X protection rating and a documented steady-state heat dissipation of 19 W.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial three-phase induction motor soft starting\u003c\/li\u003e\n\u003cli\u003eConveyor and material handling equipment\u003c\/li\u003e\n\u003cli\u003eCentrifugal pump motor starting and stopping\u003c\/li\u003e\n\u003cli\u003eIndustrial ventilation fans and blowers\u003c\/li\u003e\n\u003cli\u003ePackaging and manufacturing machinery\u003c\/li\u003e\n\u003cli\u003eMotor control cabinets using 24V AC\/DC control circuits\u003c\/li\u003e\n\u003cli\u003eMechanical equipment requiring controlled motor acceleration\u003c\/li\u003e\n\u003cli\u003eSMC-3 motor starter maintenance and replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003ePurchase Information\u003c\/h2\u003e\n\u003cp\u003eWe support online purchase of the Allen-Bradley 150-C30NBR Soft Starter. If you need to make bulk purchases and inquire about other products, please contact our team to inform us of your purchase requirements. We will provide you with information such as quantity quotations, delivery dates, and transportation methods.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is Allen-Bradley 150-C30NBR?\u003c\/strong\u003e\u003cbr\u003eAllen-Bradley 150-C30NBR is a Bulletin 150-C SMC-3 solid-state soft starter rated at 30 A, designed for three-phase motor starting with a nominal 480 VAC main power supply and 24 V AC\/DC control power.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated current of 150-C30NBR?\u003c\/strong\u003e\u003cbr\u003eThe controller has a 30 A current rating. Rockwell Automation specifies a line-connected motor current range of 10-30 A for supported 380\/400\/415\/460 VAC installations.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat control voltage does 150-C30NBR require?\u003c\/strong\u003e\u003cbr\u003eThis model requires 24 V AC\/DC control power. The documented current during starting with the fan operating is 800 mA at 24 VDC or 660 mA at 24 VAC.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between 150-C30NBR and 150-C30NBD?\u003c\/strong\u003e\u003cbr\u003eThe 150-C30NBR uses 24 V AC\/DC control power, while the 150-C30NBD uses a 100-240 VAC control supply. These models must not be substituted without confirming the existing control circuit voltage.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat motor horsepower range does 150-C30NBR support?\u003c\/strong\u003e\u003cbr\u003eManufacturer data specifies 7.5-20 HP for line-connected motors at 460 VAC and 7.5-30 HP for supported inside-delta connections at 460 VAC. Actual selection depends on motor full-load current and starting duty.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eDoes 150-C30NBR support inside-delta motor connections?\u003c\/strong\u003e\u003cbr\u003eYes. The documented inside-delta motor current range is 17.3-52 A at the applicable 380\/400\/415\/460 VAC operating conditions. Wiring and circuit protection must follow the manufacturer installation requirements.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eDoes 150-C30NBR include an internal bypass?\u003c\/strong\u003e\u003cbr\u003eYes. The controller includes an integrated bypass to reduce power losses during the applicable full-speed motor running condition.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat current limit settings are available?\u003c\/strong\u003e\u003cbr\u003eThe available settings are 150%, 250%, 350% and 450% of motor full-load current. Starting times, initial torque and kick-start duration are also configurable.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eDoes 150-C30NBR include electronic overload protection?\u003c\/strong\u003e\u003cbr\u003eYes. The starter includes electronic motor overload protection with selectable Class 10, 15 and 20 trip settings. The selected settings must be matched to the connected motor and application.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eCan 150-C30NBR perform soft stopping?\u003c\/strong\u003e\u003cbr\u003eYes. Soft stopping can be disabled or configured to 100%, 200% or 300% of the selected starting time when the controller is correctly wired and configured.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eDoes 150-C30NBR have an integrated display or fault contact?\u003c\/strong\u003e\u003cbr\u003eThe module does not include an integrated display. It provides one normally open overload\/fault auxiliary contact at terminals 97-98, rated at 0.6 A at 120 VAC or 0.3 A at 240 VAC.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should be checked before ordering 150-C30NBR?\u003c\/strong\u003e\u003cbr\u003eVerify the complete catalog number 150-C30NBR, 30 A controller rating, main supply voltage, 24 V AC\/DC control power, motor nameplate current, line or inside-delta wiring, overload trip class, current limit settings, fault contact wiring, IP2X protection and 139.7 × 44.8 × 110 mm installation dimensions.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/main\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67734921412687,"sku":"LL1-AB-150C30NBR","price":387.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/7569\/2623\/files\/150-C30NBR-01-_02.jpg?v=1792132651","url":"https:\/\/yunshuotrade.com\/products\/allen-bradley-150-c30nbr-controller","provider":"yunshuotrade","version":"1.0","type":"link"}