{"product_id":"allen-bradley-150-c108nbd-controller","title":"Allen-Bradley 150-C108NBD Smart Motor Controller  Fast Shipping","description":"\u003cstyle\u003e.nxs-industrial-product-page{--industrial-navy:#082f49;--industrial-blue:#0b4f7c;--industrial-blue-2:#0f6ea8;--industrial-blue-3:#1784c1;--industrial-cyan:#38bdf8;--steel-blue:#dcebf5;--steel-line:#c9dce9;--surface:#fff;--surface-soft:#f7fbfe;--text-main:#173042;--shadow-soft:0 10px 30px rgba(8,47,73,.08);--shadow-hover:0 16px 36px rgba(8,79,124,.15);--radius-lg:14px;--radius-md:10px}.nxs-industrial-product-page,.nxs-industrial-product-page *{margin:0;padding:0;box-sizing:border-box;font-family:Arial,Helvetica,sans-serif}.nxs-industrial-product-page{background:linear-gradient(180deg,#eef6fb 0,#f7fafc 320px,#eef3f7 100%);position:relative;overflow:hidden;color:var(--text-main);line-height:1.75;-webkit-font-smoothing:antialiased}.nxs-industrial-product-page .container{width:92%;max-width:1120px;margin:0 auto;padding-bottom:34px}.nxs-industrial-product-page main{padding-top:8px}.nxs-industrial-product-page .section{position:relative;overflow:hidden;background:var(--surface);margin:22px auto;padding:36px 30px;border:1px solid var(--steel-line);border-radius:var(--radius-lg);box-shadow:var(--shadow-soft)}.nxs-industrial-product-page .section::before{content:'';position:absolute;left:0;top:0;width:5px;height:100%;background:linear-gradient(180deg,var(--industrial-blue-3),var(--industrial-blue))}.nxs-industrial-product-page .section h2{display:inline-flex;align-items:center;gap:10px;font-size:25px;line-height:1.3;color:var(--industrial-navy);margin-bottom:24px}.nxs-industrial-product-page .section h2::before{content:'';width:28px;height:4px;flex:0 0 28px;border-radius:999px;background:linear-gradient(90deg,var(--industrial-blue-2),var(--industrial-cyan))}.nxs-industrial-product-page .spec-table{width:100%;border-collapse:separate;border-spacing:0;overflow:hidden;border:1px solid var(--steel-line);border-radius:var(--radius-md);background:#fff}.nxs-industrial-product-page .spec-table tr:nth-child(even){background:#f7fbfe}.nxs-industrial-product-page .spec-table tr:hover{background:#eaf5fb}.nxs-industrial-product-page .spec-table td{padding:13px 16px;border-bottom:1px solid #dbe7ef;vertical-align:top;color:#294658}.nxs-industrial-product-page .spec-table tr:last-child td{border-bottom:none}.nxs-industrial-product-page .spec-table td:first-child{width:38%;font-weight:700;color:#0b456d;background:rgba(220,235,245,.42)}.nxs-industrial-product-page .spec-table a{color:#0f6ea8;text-decoration:underline;overflow-wrap:anywhere}.nxs-industrial-product-page .features{display:grid;grid-template-columns:repeat(auto-fit,minmax(235px,1fr));gap:18px}.nxs-industrial-product-page .card{position:relative;overflow:hidden;background:linear-gradient(180deg,#fff,#f4f9fc);padding:22px 20px;border:1px solid #d5e4ee;border-radius:var(--radius-md);box-shadow:0 6px 18px rgba(8,47,73,.055);transition:transform .22s,box-shadow .22s}.nxs-industrial-product-page .card::before{content:'';position:absolute;left:0;top:0;width:100%;height:4px;background:linear-gradient(90deg,var(--industrial-blue),var(--industrial-cyan))}.nxs-industrial-product-page .card:hover{transform:translateY(-4px);box-shadow:var(--shadow-hover)}.nxs-industrial-product-page .card h3{color:var(--industrial-blue);font-size:18px;line-height:1.35;margin-bottom:10px;border-left:4px solid var(--industrial-blue-3);padding-left:12px}.nxs-industrial-product-page .card p{color:#526a79;font-size:15px}.nxs-industrial-product-page .section ul{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:11px 18px;list-style:none}.nxs-industrial-product-page .section li{position:relative;padding:12px 14px 12px 38px;background:var(--surface-soft);border:1px solid #dbe8f0;border-radius:8px;color:#365264}.nxs-industrial-product-page .section li::before{content:'';position:absolute;left:15px;top:50%;width:9px;height:9px;transform:translateY(-50%) rotate(45deg);background:var(--industrial-blue-2)}.nxs-industrial-product-page .section:nth-of-type(4) p{padding:18px 20px;background:linear-gradient(135deg,#edf7fc,#f9fcfe);border:1px solid #cfe4f1;border-left:4px solid var(--industrial-blue-2);border-radius:9px;color:#355267}.nxs-industrial-product-page .section:last-of-type{counter-reset:faq}.nxs-industrial-product-page .section:last-of-type\u003ep{position:relative;padding:18px 18px 18px 54px;background:#f8fbfd;border:1px solid #d8e6ef;border-radius:9px;counter-increment:faq}.nxs-industrial-product-page .section:last-of-type\u003ep::before{content:counter(faq,decimal-leading-zero);position:absolute;left:15px;top:17px;min-width:28px;height:28px;display:inline-flex;align-items:center;justify-content:center;border-radius:6px;background:var(--industrial-blue);color:#fff;font-size:11px;font-weight:700}.nxs-industrial-product-page .section:last-of-type\u003ep strong{display:inline-block;color:#0b456d;margin-bottom:5px;line-height:1.4}.nxs-industrial-product-page .section:last-of-type\u003ebr{display:block;content:'';margin:10px 0}@media(max-width:760px){.nxs-industrial-product-page .container{width:100%;padding:0 12px 24px}.nxs-industrial-product-page .section{padding:26px 17px 24px;margin:14px auto;border-radius:11px}.nxs-industrial-product-page .section h2{font-size:21px;margin-bottom:18px}.nxs-industrial-product-page .section h2::before{width:20px;flex-basis:20px}.nxs-industrial-product-page .spec-table{table-layout:fixed}.nxs-industrial-product-page .spec-table td{padding:11px 9px;font-size:13px;overflow-wrap:anywhere}.nxs-industrial-product-page .spec-table td:first-child{width:42%}.nxs-industrial-product-page .features,.nxs-industrial-product-page .section ul{grid-template-columns:1fr;gap:12px}.nxs-industrial-product-page .card{padding:18px 17px}.nxs-industrial-product-page .card:hover{transform:none}.nxs-industrial-product-page .section li{font-size:14px}.nxs-industrial-product-page .section:last-of-type\u003ep{padding:16px 14px 16px 48px;font-size:14px}.nxs-industrial-product-page .section:last-of-type\u003ep::before{left:12px;top:15px;min-width:26px;height:26px;font-size:10px}}@media(prefers-reduced-motion:reduce){.nxs-industrial-product-page *{transition:none!important}}\u003c\/style\u003e\n\u003cdiv class=\"nxs-industrial-product-page\"\u003e\n\u003cdiv class=\"container\"\u003e\u003cmain\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e150-C108NBD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eSoft Starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eSMC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Bulletin\u003c\/td\u003e\n\u003ctd\u003eBulletin 150-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Type\u003c\/td\u003e\n\u003ctd\u003eSolid-State Smart Motor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Controller Current\u003c\/td\u003e\n\u003ctd\u003e108 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Main Power Voltage\u003c\/td\u003e\n\u003ctd\u003e480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Power Voltage Class\u003c\/td\u003e\n\u003ctd\u003e200-480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Circuit\u003c\/td\u003e\n\u003ctd\u003eThree-Phase, 3-Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting Duty\u003c\/td\u003e\n\u003ctd\u003e350% of Motor Full-Load Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine-Connected Motor Current Range\u003c\/td\u003e\n\u003ctd\u003e27-108 A at 380\/400\/415\/460 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInside-Delta Motor Current Range\u003c\/td\u003e\n\u003ctd\u003e47-187 A at 380\/400\/415\/460 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Line-Connected Motor Power at 400\/415VAC\u003c\/td\u003e\n\u003ctd\u003e55 kW at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine-Connected Motor Power at 460VAC\u003c\/td\u003e\n\u003ctd\u003e50-75 HP at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inside-Delta Motor Power at 400\/415VAC\u003c\/td\u003e\n\u003ctd\u003e90 kW at 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInside-Delta Motor Power at 460VAC\u003c\/td\u003e\n\u003ctd\u003e40-150 HP at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Control Current During Start with Fan\u003c\/td\u003e\n\u003ctd\u003e200 mA at 120 VAC; 120 mA at 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFan Power Rating\u003c\/td\u003e\n\u003ctd\u003e20 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Control Input ON-State Voltage\u003c\/td\u003e\n\u003ctd\u003e85 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Input ON-State Current\u003c\/td\u003e\n\u003ctd\u003e9.8 mA at 120 VAC; 19.6 mA at 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelectable Current Limit\u003c\/td\u003e\n\u003ctd\u003e150%, 250%, 350% and 450% of Motor Full-Load Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelectable Start Times\u003c\/td\u003e\n\u003ctd\u003e2, 5, 10, 15, 20, 25 and 30 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelectable Initial Torque\u003c\/td\u003e\n\u003ctd\u003e15%, 25%, 35% and 65% of Locked-Rotor Torque\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelectable Kick Start Duration\u003c\/td\u003e\n\u003ctd\u003eOff, 0.5, 1.0 or 1.5 Seconds at 450% FLA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoft Stop Configuration\u003c\/td\u003e\n\u003ctd\u003eOff, 100%, 200% or 300% of Selected Start Time When Wired\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Motor Overload Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelectable Overload Trip Classes\u003c\/td\u003e\n\u003ctd\u003eClass 10, 15 and 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Bypass\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Rotation Control\u003c\/td\u003e\n\u003ctd\u003eSingle Direction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Overload\/Fault Contact\u003c\/td\u003e\n\u003ctd\u003e1 Normally Open Contact at Terminals 97-98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contact Conventional Thermal Current\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contact Operational Rating\u003c\/td\u003e\n\u003ctd\u003e0.6 A at 120 VAC; 0.3 A at 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contact Make Capacity\u003c\/td\u003e\n\u003ctd\u003e432 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contact Break Capacity\u003c\/td\u003e\n\u003ctd\u003e72 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Display\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Configuration\u003c\/td\u003e\n\u003ctd\u003eOpen Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e600 VAC per UL\/CSA\/NEMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Circuit Dielectric Withstand\u003c\/td\u003e\n\u003ctd\u003e2500 VAC per IEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Circuit dV\/dt Protection\u003c\/td\u003e\n\u003ctd\u003e1000 V\/µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection Device Performance\u003c\/td\u003e\n\u003ctd\u003eType 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum High-Capacity Available Fault Current\u003c\/td\u003e\n\u003ctd\u003e70 kA at 600 V with Specified Protective Devices and Connection Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95% Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Installation Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSteady-State Heat Dissipation\u003c\/td\u003e\n\u003ctd\u003e62 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Terminal Conductor Size\u003c\/td\u003e\n\u003ctd\u003e0.2-2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Terminal Tightening Torque\u003c\/td\u003e\n\u003ctd\u003e0.45-0.9 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Terminal Connection\u003c\/td\u003e\n\u003ctd\u003eOne M10 × 1.5 Hole per Power Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hole Diameter\u003c\/td\u003e\n\u003ctd\u003e7.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e443.7 × 196.4 × 205.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/section\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"features\"\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003e108A Three-Phase Motor Starting\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley SMC-3 150-C108NBD provides a 108 A controller rating for compatible three-phase induction motors. The documented line-connected motor current range is 27-108 A at 380\/400\/415\/460 VAC, with motor ratings of 50-75 HP at 460 VAC.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003e100-240VAC Control Supply\u003c\/h3\u003e\n\u003cp\u003eThe controller operates with a 100-240 VAC control supply and a nominal 480 VAC three-phase power circuit. This configuration is intended for compatible industrial motor control systems and differs from the 24 V AC\/DC control version.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003eIntegrated Bypass Technology\u003c\/h3\u003e\n\u003cp\u003eThe internal bypass reduces thyristor conduction losses after the motor reaches its operating condition. The manufacturer specifies 62 W steady-state heat dissipation for this model.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003eAdjustable Starting and Soft Stopping\u003c\/h3\u003e\n\u003cp\u003eSelectable current limits of 150-450% of motor full-load current, start times from 2 to 30 seconds, adjustable initial torque and configurable soft stopping help adapt motor acceleration and deceleration to compatible mechanical loads.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003eIntegrated Motor Overload Protection\u003c\/h3\u003e\n\u003cp\u003eElectronic motor overload protection includes selectable Class 10, 15 and 20 trip characteristics. A normally open overload\/fault auxiliary contact supports compatible monitoring and control circuits.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003carticle class=\"card\"\u003e\n\u003ch3\u003eIndustrial Panel Integration\u003c\/h3\u003e\n\u003cp\u003eThe open-type IP2X controller measures 443.7 × 196.4 × 205.2 mm and weighs 15 kg. It supports line-connected and inside-delta motor installations when correctly selected and wired.\u003c\/p\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial three-phase induction motor soft starting\u003c\/li\u003e\n\u003cli\u003eHeavy-duty conveyor and material handling systems\u003c\/li\u003e\n\u003cli\u003eCentrifugal pump motor starting and stopping\u003c\/li\u003e\n\u003cli\u003eIndustrial ventilation fan and blower equipment\u003c\/li\u003e\n\u003cli\u003eManufacturing and production line motor control\u003c\/li\u003e\n\u003cli\u003eMotor control cabinets using 100-240VAC control circuits\u003c\/li\u003e\n\u003cli\u003eIndustrial processing machinery requiring controlled motor acceleration\u003c\/li\u003e\n\u003cli\u003eMaintenance and replacement of compatible SMC-3 motor controllers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/section\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003ePurchase Information\u003c\/h2\u003e\n\u003cp\u003eWe support online purchase of the Allen-Bradley 150-C108NBD Soft Starter. If you need to make bulk purchases and inquire about other products, please contact our team to inform us of your purchase requirements. We will provide you with information such as quantity quotations, delivery dates, and transportation methods.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003csection class=\"section\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is Allen-Bradley 150-C108NBD?\u003c\/strong\u003e\u003cbr\u003eAllen-Bradley 150-C108NBD is a Bulletin 150-C SMC-3 solid-state smart motor controller rated at 108 A, designed for compatible three-phase induction motors with a nominal 480 VAC main power circuit and 100-240 VAC control supply.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated current of 150-C108NBD?\u003c\/strong\u003e\u003cbr\u003eThe controller has a 108 A current rating. Rockwell Automation specifies a line-connected motor current range of 27-108 A for supported 380\/400\/415\/460 VAC applications.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat control voltage does 150-C108NBD require?\u003c\/strong\u003e\u003cbr\u003eThis model uses 100-240 VAC control power. The manufacturer's specified control current during starting with the fan operating is 200 mA at 120 VAC or 120 mA at 240 VAC.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between 150-C108NBD and 150-C108NBR?\u003c\/strong\u003e\u003cbr\u003eThe 150-C108NBD uses a 100-240 VAC control supply, while the 150-C108NBR uses 24 V AC\/DC control power. These configurations must not be interchanged without checking the control supply and fan power requirements.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat motor horsepower range does 150-C108NBD support?\u003c\/strong\u003e\u003cbr\u003eManufacturer selection data identifies a 50-75 HP range for line-connected motors at 460 VAC. Motor full-load current, starting duty and installation requirements must also be considered.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eDoes 150-C108NBD support inside-delta motor connections?\u003c\/strong\u003e\u003cbr\u003eYes. Rockwell Automation specifies an inside-delta motor current range of 47-187 A for compatible 380\/400\/415\/460 VAC installations. Wiring and protective device selection must follow the installation instructions.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eDoes 150-C108NBD include an internal bypass?\u003c\/strong\u003e\u003cbr\u003eYes. The controller includes an integrated bypass to reduce power losses and heat generation during the applicable full-speed motor running condition.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat starting current limits are available?\u003c\/strong\u003e\u003cbr\u003eThe selectable current limits are 150%, 250%, 350% and 450% of motor full-load current. The controller also provides configurable starting times, initial torque and kick-start settings.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eDoes 150-C108NBD include electronic motor overload protection?\u003c\/strong\u003e\u003cbr\u003eYes. Integrated motor overload protection supports Class 10, 15 and 20 trip settings. The selected protection settings must be appropriate for the connected motor and operating duty.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eCan 150-C108NBD perform soft stopping?\u003c\/strong\u003e\u003cbr\u003eYes. Soft stopping can be disabled or configured to 100%, 200% or 300% of the selected starting time when the starter is properly wired and configured.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eDoes 150-C108NBD have an integrated display or fault contact?\u003c\/strong\u003e\u003cbr\u003eThe controller does not include an integrated display. It provides one normally open overload\/fault auxiliary contact at terminals 97-98, with operational ratings of 0.6 A at 120 VAC or 0.3 A at 240 VAC.\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should be checked before ordering 150-C108NBD?\u003c\/strong\u003e\u003cbr\u003eVerify the exact catalog number 150-C108NBD, 108 A controller rating, nominal 480 VAC three-phase main supply, 100-240 VAC control voltage, motor full-load current, line or inside-delta wiring, overload trip class, starting duty, fan power requirements, fault contact connections, protective devices, IP2X construction and 443.7 × 196.4 × 205.2 mm installation dimensions.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003c\/main\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67735185752143,"sku":"LL1-AB-150C108NBD","price":1770.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/7569\/2623\/files\/150-C108NBD-02-_01.jpg?v=1792137231","url":"https:\/\/yunshuotrade.com\/products\/allen-bradley-150-c108nbd-controller","provider":"yunshuotrade","version":"1.0","type":"link"}