{"product_id":"allen-bradley-140m-c2e-c20-motor","title":"Allen-Bradley 140M-C2E-C20 Motor Protection Circuit Breaker 14.5-20A 3-Pole","description":"\u003cstyle\u003e.nxs-industrial-product-page{--navy:#082f49;--blue:#0b4f7c;--blue2:#0f6ea8;--cyan:#38bdf8;--border:#c9dce9;--text:#173042;font-family:Arial,Helvetica,sans-serif;color:var(--text);line-height:1.75;background:linear-gradient(180deg,#eef6fb,#f7fafc 320px,#eef3f7);padding:18px 0 36px}.nxs-industrial-product-page *{box-sizing:border-box}.nxs-industrial-product-page .container{width:92%;max-width:1120px;margin:auto}.nxs-industrial-product-page .section{position:relative;background:#fff;border:1px solid var(--border);border-radius:14px;margin:22px 0;padding:34px 30px;box-shadow:0 10px 30px rgba(8,47,73,.08);overflow:hidden}.nxs-industrial-product-page .section:before{content:'';position:absolute;left:0;top:0;width:5px;height:100%;background:linear-gradient(var(--blue2),var(--blue))}.nxs-industrial-product-page h2{font-size:25px;line-height:1.3;color:var(--navy);margin:0 0 23px;display:flex;align-items:center;gap:10px}.nxs-industrial-product-page h2:before{content:'';width:28px;height:4px;background:linear-gradient(90deg,var(--blue2),var(--cyan));border-radius:3px;flex-shrink:0}.nxs-industrial-product-page .spec-table{width:100%;border-collapse:separate;border-spacing:0;border:1px solid var(--border);border-radius:10px;overflow:hidden}.nxs-industrial-product-page .spec-table tr:nth-child(even){background:#f7fbfe}.nxs-industrial-product-page .spec-table tr:hover{background:#eaf5fb}.nxs-industrial-product-page .spec-table td{padding:12px 15px;border-bottom:1px solid #dbe7ef;vertical-align:top;overflow-wrap:anywhere}.nxs-industrial-product-page .spec-table tr:last-child td{border-bottom:0}.nxs-industrial-product-page .spec-table td:first-child{width:39%;font-weight:bold;color:#0b456d;background:rgba(220,235,245,.4)}.nxs-industrial-product-page a{color:var(--blue2);overflow-wrap:anywhere}.nxs-industrial-product-page .features{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:17px}.nxs-industrial-product-page .card{position:relative;background:linear-gradient(#fff,#f4f9fc);border:1px solid #d5e4ee;border-radius:10px;padding:22px 20px;box-shadow:0 6px 18px rgba(8,47,73,.055);transition:transform .2s,box-shadow .2s}.nxs-industrial-product-page .card:before{content:'';position:absolute;left:0;top:0;width:100%;height:4px;background:linear-gradient(90deg,var(--blue),var(--cyan))}.nxs-industrial-product-page .card:hover{transform:translateY(-3px);box-shadow:0 15px 30px rgba(8,79,124,.13)}.nxs-industrial-product-page .card h3{font-size:18px;color:var(--blue);line-height:1.4;border-left:4px solid var(--blue2);padding-left:12px;margin:0 0 10px}.nxs-industrial-product-page .card p{margin:0;color:#526a79;font-size:15px}.nxs-industrial-product-page ul{list-style:none;padding:0;margin:0;display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:11px 16px}.nxs-industrial-product-page li{position:relative;padding:12px 13px 12px 37px;background:#f7fbfe;border:1px solid #dbe8f0;border-radius:8px}.nxs-industrial-product-page li:before{content:'';position:absolute;left:15px;top:21px;width:9px;height:9px;transform:rotate(45deg);background:var(--blue2)}.nxs-industrial-product-page .section:nth-of-type(4)\u003ep{background:#edf7fc;border:1px solid #cfe4f1;border-left:4px solid var(--blue2);padding:18px;border-radius:9px;margin:0}.nxs-industrial-product-page .section:last-of-type{counter-reset:faq}.nxs-industrial-product-page .section:last-of-type\u003ep{position:relative;background:#f8fbfd;border:1px solid #d8e6ef;border-radius:9px;padding:16px 18px 16px 53px;margin:0;counter-increment:faq}.nxs-industrial-product-page .section:last-of-type\u003ep:before{content:counter(faq,decimal-leading-zero);position:absolute;left:14px;top:16px;background:var(--blue);color:#fff;font-size:11px;font-weight:bold;padding:4px 6px;border-radius:5px}.nxs-industrial-product-page .section:last-of-type\u003ep strong{color:#0b456d}.nxs-industrial-product-page .section:last-of-type\u003ebr{display:block;content:'';margin:10px 0}@media(max-width:760px){.nxs-industrial-product-page .container{width:100%;padding:0 12px}.nxs-industrial-product-page .section{margin:14px 0;padding:25px 16px;border-radius:11px}.nxs-industrial-product-page h2{font-size:21px}.nxs-industrial-product-page h2:before{width:20px}.nxs-industrial-product-page .spec-table{table-layout:fixed}.nxs-industrial-product-page .spec-table td{padding:10px 8px;font-size:13px;line-height:1.55}.nxs-industrial-product-page .spec-table td:first-child{width:43%}.nxs-industrial-product-page .features,.nxs-industrial-product-page ul{grid-template-columns:1fr}.nxs-industrial-product-page .card{padding:18px 16px}.nxs-industrial-product-page .card:hover{transform:none}.nxs-industrial-product-page li{font-size:14px}.nxs-industrial-product-page .section:last-of-type\u003ep{font-size:14px;padding-left:47px}.nxs-industrial-product-page .section:last-of-type\u003ep:before{left:11px}}@media(prefers-reduced-motion:reduce){.nxs-industrial-product-page *{transition:none!important}}\u003c\/style\u003e\u003cdiv class=\"nxs-industrial-product-page\"\u003e\u003cdiv class=\"container\"\u003e\u003cmain\u003e\u003csection class=\"section\"\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e140M-C2E-C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Category\u003c\/td\u003e\n\u003ctd\u003eMotor Protection Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003e140M IEC Circuit Breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Bulletin\u003c\/td\u003e\n\u003ctd\u003eBulletin 140M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eManual Motor Protection Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Technology\u003c\/td\u003e\n\u003ctd\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Current (Ie)\u003c\/td\u003e\n\u003ctd\u003e20 A per IEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable Thermal Overload Setting Range\u003c\/td\u003e\n\u003ctd\u003e14.5-20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload Trip Class\u003c\/td\u003e\n\u003ctd\u003eClass 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnetic Short-Circuit Release\u003c\/td\u003e\n\u003ctd\u003eFixed, 260 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnetic Release Characteristic\u003c\/td\u003e\n\u003ctd\u003eApproximately 13 Times Maximum Rated Current; Manufacturer Tolerance Applies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Failure Sensitivity\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Loss Protection\u003c\/td\u003e\n\u003ctd\u003eDifferential Release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Rated Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e690 VAC per IEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltimate Short-Circuit Breaking Capacity (Icu) at 230\/240VAC\u003c\/td\u003e\n\u003ctd\u003e65 kA per IEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltimate Short-Circuit Breaking Capacity (Icu) at 400VAC\u003c\/td\u003e\n\u003ctd\u003e50 kA per IEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Short-Circuit Breaking Capacity (Ics) at 500VAC\u003c\/td\u003e\n\u003ctd\u003e6 kA per IEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Type 2 Coordination Short-Circuit Current at 400VAC\u003c\/td\u003e\n\u003ctd\u003e50 kA with Applicable Contactor and Coordination Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf-Protected Combination Motor Controller SCCR\u003c\/td\u003e\n\u003ctd\u003e10 kA at 480Y\/277 V in the Specified UL 508 Type E Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGroup Motor Installation Short-Circuit Rating\u003c\/td\u003e\n\u003ctd\u003e30 kA at 600 V under Specified UL 508 Installation Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Three-Phase Motor Rating at 230\/240VAC\u003c\/td\u003e\n\u003ctd\u003e5.5 kW per IEC AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Three-Phase Motor Rating at 400VAC\u003c\/td\u003e\n\u003ctd\u003e10 kW per IEC AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Three-Phase Motor Rating at 690VAC\u003c\/td\u003e\n\u003ctd\u003e17 kW per IEC AC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Three-Phase Motor Horsepower at 230VAC\u003c\/td\u003e\n\u003ctd\u003e7.5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eC Frame, 32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Mechanism\u003c\/td\u003e\n\u003ctd\u003eRotary Control Knob\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Circuit Connections\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Auxiliary Contacts\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Undervoltage Release\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Endurance\u003c\/td\u003e\n\u003ctd\u003e100,000 Operations at Maximum Rated Operational Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Frequency\u003c\/td\u003e\n\u003ctd\u003e25 Operations per Hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Power Loss at Rated Load\u003c\/td\u003e\n\u003ctd\u003e6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Protection Rating\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Installation Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eCompensated from -20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Derating at 60°C\u003c\/td\u003e\n\u003ctd\u003eNo Current Reduction Under Specified Manufacturer Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e45 × 90 × 74.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscontinuation Date\u003c\/td\u003e\n\u003ctd\u003eFebruary 18, 2022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Replacement Category\u003c\/td\u003e\n\u003ctd\u003eEngineering Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer-Listed Replacement\u003c\/td\u003e\n\u003ctd\u003e140MT-C3E-C20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Documentation\u003c\/td\u003e\n\u003ctd\u003e140M-TD002 Motor Protection Circuit Breaker and Motor Circuit Protector Specifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Product Reference\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.rockwellautomation.com\/en-us\/products\/details.140M-C2E-C20.html\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eRockwell Automation 140M-C2E-C20 Product Specifications\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnical Data Reference\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/td\/140m-td002_-en-p.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eRockwell Automation 140M-TD002 Technical Data\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/section\u003e\u003csection class=\"section\"\u003e\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cdiv class=\"features\"\u003e\n\u003carticle class=\"card\"\u003e\u003ch3\u003eAdjustable 14.5-20A Motor Protection\u003c\/h3\u003e\n\u003cp\u003eThe Allen-Bradley 140M-C2E-C20 provides adjustable thermal overload protection across a 14.5-20 A setting range. Its Class 10 trip characteristic is designed for compatible three-phase motors requiring appropriately coordinated overload protection.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"card\"\u003e\u003ch3\u003eThree-Pole Thermal-Magnetic Design\u003c\/h3\u003e\n\u003cp\u003eThree-pole construction combines adjustable thermal overload protection with a fixed 260 A magnetic short-circuit release. The device also incorporates differential phase-loss protection to respond to specified motor supply imbalance conditions.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"card\"\u003e\u003ch3\u003eHigh Short-Circuit Breaking Capacity\u003c\/h3\u003e\n\u003cp\u003eThe circuit breaker has an IEC ultimate breaking capacity of 50 kA at 400 VAC and 65 kA at 230\/240 VAC. Actual permissible fault current depends on the operating voltage, applicable standard, coordination method and protective equipment configuration.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"card\"\u003e\u003ch3\u003eUp to 690VAC IEC Application\u003c\/h3\u003e\n\u003cp\u003eThe 140M-C2E-C20 is rated for maximum operating voltage of 690 VAC per IEC at 50\/60 Hz. Manufacturer motor selection data lists 10 kW at 400 VAC for standard three-phase AC-3 motor switching.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"card\"\u003e\u003ch3\u003eManual Rotary Operation\u003c\/h3\u003e\n\u003cp\u003eA rotary control knob provides manual switching and reset operation. The device uses screw-type main circuit terminals and does not include factory-installed auxiliary contacts or an undervoltage release in the standard configuration.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"card\"\u003e\u003ch3\u003eCompact Motor Control Panel Integration\u003c\/h3\u003e\n\u003cp\u003eThe C-frame breaker measures 45 × 90 × 74.5 mm and features IP2X construction. It is suited to compatible motor control assemblies where the overload range, short-circuit ratings and associated contactor arrangement have been verified.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\u003c\/section\u003e\u003csection class=\"section\"\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThree-phase induction motor overload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eIndustrial conveyor motor starter assemblies\u003c\/li\u003e\n\u003cli\u003ePump motor control and protection circuits\u003c\/li\u003e\n\u003cli\u003eIndustrial ventilation fan and blower motor protection\u003c\/li\u003e\n\u003cli\u003eManufacturing equipment motor control panels\u003c\/li\u003e\n\u003cli\u003eMotor starter assemblies using compatible 100-C contactors\u003c\/li\u003e\n\u003cli\u003eIndustrial machine electrical cabinet maintenance\u003c\/li\u003e\n\u003cli\u003eReplacement and servicing of compatible Bulletin 140M motor protection devices\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/section\u003e\u003csection class=\"section\"\u003e\u003ch2\u003ePurchase Information\u003c\/h2\u003e\n\u003cp\u003eWe support online purchase of the Allen-Bradley 140M-C2E-C20 Motor Protection Circuit Breaker. If you need to make bulk purchases and inquire about other products, please contact our team to inform us of your purchase requirements. We will provide you with information such as quantity quotations, delivery dates, and transportation methods.\u003c\/p\u003e\u003c\/section\u003e\u003csection class=\"section\"\u003e\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is Allen-Bradley 140M-C2E-C20?\u003c\/strong\u003e\u003cbr\u003eAllen-Bradley 140M-C2E-C20 is a three-pole Bulletin 140M motor protection circuit breaker with an adjustable 14.5-20 A thermal overload range, fixed magnetic short-circuit protection and Class 10 overload trip characteristics.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eWhat is the adjustable current range of 140M-C2E-C20?\u003c\/strong\u003e\u003cbr\u003eThe thermal overload release can be adjusted between 14.5 A and 20 A. The setting should be selected according to the connected motor nameplate current and the applicable manufacturer coordination requirements.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eHow many poles does 140M-C2E-C20 have?\u003c\/strong\u003e\u003cbr\u003eThe circuit breaker has three poles, allowing it to protect compatible three-phase motor circuits through a single motor protection device.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eWhat is the magnetic trip current?\u003c\/strong\u003e\u003cbr\u003eThe magnetic short-circuit release is fixed at 260 A, approximately 13 times the maximum 20 A rated operational current. The manufacturer's tolerance and applicable coordination conditions must be considered.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eWhat is the maximum operating voltage?\u003c\/strong\u003e\u003cbr\u003eThe manufacturer specifies a maximum rated operating voltage of 690 VAC per IEC, with a rated frequency of 50\/60 Hz. The permissible breaking capacity differs with the applied voltage.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eWhat is the short-circuit breaking capacity at 400VAC?\u003c\/strong\u003e\u003cbr\u003eThe IEC ultimate short-circuit breaking capacity, Icu, is 50 kA at 400 VAC. This must not be confused with the service breaking capacity or a UL short-circuit current rating, which may have different values and conditions.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eDoes 140M-C2E-C20 provide motor overload and phase-loss protection?\u003c\/strong\u003e\u003cbr\u003eYes. The device incorporates adjustable thermal overload protection with Class 10 trip characteristics and differential phase-loss protection. Correct application requires verification of the motor and installation conditions.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eWhat motor power can 140M-C2E-C20 protect?\u003c\/strong\u003e\u003cbr\u003eManufacturer AC-3 selection data identifies standard three-phase motor ratings of 5.5 kW at 230\/240 VAC, 10 kW at 400 VAC and 17 kW at 690 VAC. These are application selection ratings rather than a substitute for checking the motor full-load current.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eDoes 140M-C2E-C20 include auxiliary contacts?\u003c\/strong\u003e\u003cbr\u003eNo. The standard breaker configuration does not have integrated auxiliary contacts or an undervoltage release. Any additional indication or tripping accessories must be selected separately according to the compatible product documentation.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eWhat is the difference between 140M-C2E-C20 and 140M-C2E-C16?\u003c\/strong\u003e\u003cbr\u003eThe 140M-C2E-C20 has a 14.5-20 A adjustable overload range and 260 A fixed magnetic release. The 140M-C2E-C16 has a 10-16 A adjustable range and a different magnetic trip rating. They are not interchangeable without verifying the connected motor protection requirements.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eIs Allen-Bradley 140M-C2E-C20 discontinued?\u003c\/strong\u003e\u003cbr\u003eYes. Rockwell Automation lists the 140M-C2E-C20 as discontinued effective February 18, 2022. The manufacturer identifies 140MT-C3E-C20 as an engineering replacement, meaning dimensions, wiring, accessories and protection coordination should be assessed before migration.\u003c\/p\u003e\n\u003cbr\u003e\u003cp\u003e\u003cstrong\u003eWhat should be checked before ordering 140M-C2E-C20?\u003c\/strong\u003e\u003cbr\u003eVerify the exact catalog number 140M-C2E-C20, three-pole construction, 14.5-20 A overload adjustment range, Class 10 trip characteristics, 260 A magnetic release, motor nameplate current, supply voltage, prospective short-circuit current, applicable IEC or UL ratings, existing contactor and accessory compatibility, screw-terminal connections, 45 × 90 × 74.5 mm dimensions and discontinued product status before selecting the device for a motor control application.\u003c\/p\u003e\u003c\/section\u003e\u003c\/main\u003e\u003c\/div\u003e\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67736138481743,"sku":"LL1-AB-140MC2EC20","price":75.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0710\/7569\/2623\/files\/140M-C2E-C20-01.jpg?v=1792140348","url":"https:\/\/yunshuotrade.com\/products\/allen-bradley-140m-c2e-c20-motor","provider":"yunshuotrade","version":"1.0","type":"link"}